INSPECTION
Inspection · Vehicles built from Nov 2005
| INSPECT INTEGRATION RELAY |
![]() ![]() |
Inspect ECD (30A) fuse.
Disconnect the fuse.
Using an ohmmeter, measure the resistance of the fuse.
- Standard resistance:
Tester Connection
Specified condition
1 - 2
Below 1 Ω
Inspect ECD relay.
Using an ohmmeter, measure the resistance between the terminals.
- Standard resistance:
Tester Connection
Specified condition
A5 - C1
Below 1 Ω
A5 - A8
10 kΩ or higher
A8 - C1
10 kΩor higher
A5 - A8
Below 1 Ω
(Apply battery voltage between terminals A2 and A3)
A8 - C1
Below 1 Ω
(Apply battery voltage between terminals A2 and A3)
- NOTICE:
- While using the battery for the inspection, do not bring the positive and negative tester probes too close to each other as a short circuit may occur.