INSPECTION
Inspection · Vehicles built from Aug 2005
| INSPECT CAMSHAFT TIMING OIL CONTROL VALVE ASSEMBLY |
![]() ![]() |
Check the resistance.
Using an ohmmeter, measure the resistance between the terminals.
- Standard resistance:
Tester Connection
Specified Condition
1 (+B) - 2 (GND)
6.9 to 7.9 Ω at 20°C (68°F)
Check the operation.

Connect the positive (+) lead from the battery to terminal 1 (+) and the negative (-) lead to terminal 2 (-), then check the movement of the spool valve.
- NOTICE:
- Do not bring the positive and negative tester probes too close to each other while using the battery for inspection as short circuit may occur.
- Confirm that the spool valve moves freely and does not stick in any position.
- Do not bring the positive and negative tester probes too close to each other while using the battery for inspection as short circuit may occur.
- HINT:
- Poor returning of the spool valve resulting from contamination causes subtle pressure leak in the advance direction. In such a case, a DTC will be detected.