INSPECTION
Inspection · Vehicles built from Nov 2005
| INSPECT CRANKSHAFT POSITION SENSOR |
Check the resistance.

Using an ohmmeter, measure the resistance between the terminals.
- Standard resistance:
Temperature
Specified Condition
Cold
1,630 to 2,740 Ω
Hot
2,065 to 3,225 Ω
- HINT: