INSPECTION
Inspection · Vehicles built from Jan 2006
| INSPECT POWER WINDOW REGULATOR MASTER SWITCH ASSEMBLY |
for LHD:

Check the resistance.Using an ohmmeter, measure the resistance and check the results in accordance with the value(s) in the tables below.
- Standard Resistance:
- Driver switch:
Window Lock Switch Condition
Power Window Switch Condition
Tester Connection
Specified Condition
Always
(ON / OFF)
UP
3 (U) - 6 (B)
1 (E) - 4 (D)
Below 1 Ω
Always
(ON / OFF)
OFF
1 (E) - 3 (U)
1 (E) - 4 (D)
Below 1 Ω
Always
(ON / OFF)
DOWN MANUAL
4 (D) - 6 (B)
1 (E) - 3 (U)
Below 1 Ω
Always
(ON / OFF)
DOWN AUTO
1 (E) - 3 (U)
4 (D) - 6 (B)
Below 1 Ω
- Standard Resistance:
- Passenger side switch:
Window Lock Switch Condition
Power Window Switch Condition
Tester Connection
Specified Condition
OFF
UP
6 (B) - 16 (U)
1 (E) - 15 (D)
Below 1 Ω
OFF
OFF
1 (E) - 16 (U)
1 (E) - 15 (D)
Below 1 Ω
OFF
DOWN
6 (B) - 15 (D)
1 (E) - 16 (U)
Below 1 Ω
ON
UP
6 (B) - 16 (U)
Below 1 Ω
ON
UP
1 (E) - 15 (D)
10 kΩ or higher
ON
OFF
15 (D) - 16 (U)
Below 1 Ω
ON
DOWN
6 (B) - 15 (D)
Below 1 Ω
ON
DOWN
1 (E) - 16 (U)
10 kΩ or higher
- Standard Resistance:
- Rear LH side switch:
Window Lock Switch Condition
Power Window Switch Condition
Tester Connection
Specified Condition
OFF
UP
6 (B) - 12 (U)
1 (E) - 13 (D)
Below 1 Ω
OFF
OFF
1 (E) - 12 (U)
1 (E) - 13 (D)
Below 1 Ω
OFF
DOWN
6 (B) - 13 (D)
1 (E) - 12 (U)
Below 1 Ω
ON
UP
6 (B) - 12 (U)
Below 1 Ω
ON
UP
1 (E) - 13 (D)
10 kΩ or higher
ON
OFF
12 (U) - 13 (D)
Below 1 Ω
ON
DOWN
6 (B) - 13 (D)
Below 1 Ω
ON
DOWN
1 (E) - 12 (U)
10 kΩ or higher
- Standard Resistance:
- Rear RH side switch:
Window Lock Switch Condition
Power Window Switch Condition
Tester Connection
Specified Condition
OFF
UP
6 (B) - 10 (U)
1 (E) - 18 (D)
Below 1 Ω
OFF
OFF
1 (E) - 10 (U)
1 (E) - 18 (D)
Below 1 Ω
OFF
DOWN
6 (B) - 18 (D)
1 (E) - 10 (U)
Below 1 Ω
ON
UP
6 (B) - 10 (U)
Below 1 Ω
ON
UP
1 (E) - 18 (D)
10 kΩ or higher
ON
OFF
10 (U) - 18 (D)
Below 1 Ω
ON
DOWN
6 (B) - 18 (D)
Below 1 Ω
ON
DOWN
1 (E) - 10 (U)
10 kΩ or higher
for LHD:
Check the illumination operation.Apply battery voltage to the power window regulator master switch and check that the illumination comes on.
- Standard:
Measurement Condition
Specified Condition
Battery positive (+) → Terminal 6 (B)
Battery negative (-) → Terminal 1 (E)
Illumination comes on
for RHD:

Check the resistance.Using an ohmmeter, measure the resistance and check the results in accordance with the value(s) in the tables below.
- Standard Resistance:
- Driver switch:
Window Lock Switch Condition
Power Window Switch Condition
Tester Connection
Specified Condition
Always
(ON / OFF)
UP
4 (U) - 6 (B)
9 (E) - 3 (D)
Below 1 Ω
Always
(ON / OFF)
OFF
9 (E) - 4 (U)
9 (E) - 3 (D)
Below 1 Ω
Always
(ON / OFF)
DOWN MANUAL
3 (D) - 6 (B)
9 (E) - 4 (U)
Below 1 Ω
Always
(ON / OFF)
DOWN AUTO
9 (E) - 4 (U)
3 (D) - 6 (B)
Below 1 Ω
- Standard Resistance:
- Passenger side switch:
Window Lock Switch Condition
Power Window Switch Condition
Tester Connection
Specified Condition
OFF
UP
6 (B) - 12(U)
9 (E) - 13 (D)
Below 1 Ω
OFF
OFF
9 (E) - 12(U)
9 (E) - 13 (D)
Below 1 Ω
OFF
DOWN
6 (B) - 13 (D)
9 (E) - 12(U)
Below 1 Ω
ON
UP
6 (B) - 12(U)
Below 1 Ω
ON
UP
9 (E) - 13 (D)
10 kΩ or higher
ON
OFF
13 (D) - 12(U)
Below 1 Ω
ON
DOWN
6 (B) - 13 (D)
Below 1 Ω
ON
DOWN
9 (E) - 12 (U)
10 kΩ or higher
- Standard Resistance:
- Rear LH side switch:
Window Lock Switch Condition
Power Window Switch Condition
Tester Connection
Specified Condition
OFF
UP
6 (B) - 18 (U)
9 (E) - 10 D)
Below 1 Ω
OFF
OFF
9 (E) - 18 (U)
9 (E) - 10 (D)
Below 1 Ω
OFF
DOWN
6 (B) - 10 (D)
9 (E) - 18 (U)
Below 1 Ω
ON
UP
6 (B) - 18 (U)
Below 1 Ω
ON
UP
9 (E) - 10 (D)
10 kΩ or higher
ON
OFF
18 (U) - 10 (D)
Below 1 Ω
ON
DOWN
6 (B) - 10 (D)
Below 1 Ω
ON
DOWN
9 (E) - 18 (U)
10 kΩ or higher
- Standard Resistance:
- Rear RH side switch:
Window Lock Switch Condition
Power Window Switch Condition
Tester Connection
Specified Condition
OFF
UP
6 (B) - 16 (U)
9 (E) - 15 (D)
Below 1 Ω
OFF
OFF
9 (E) - 16 (U)
9 (E) - 15 (D)
Below 1 Ω
OFF
DOWN
6 (B) - 15 (D)
9 (E) - 16 (U)
Below 1 Ω
ON
UP
6 (B) - 16 (U)
Below 1 Ω
ON
UP
9 (E) - 15 (D)
10 kΩ or higher
ON
OFF
16 (U) - 15 (D)
Below 1 Ω
ON
DOWN
6 (B) - 15 (D)
Below 1 Ω
ON
DOWN
9 (E) - 16 (U)
10 kΩ or higher
for RHD:
Check the illumination operation.Apply battery voltage to the power window regulator master switch and check that the illumination comes on.
- Standard:
Measurement Condition
Specified Condition
Battery positive (+) → Terminal 6 (B)
Battery negative (-) → Terminal 9 (E)
Illumination comes on