INSPECTION
Inspection · Vehicles built from Aug 2005
| INSPECT REAR DOOR LOCK ASSEMBLY LH (w/ Double Locking System) |
![]() ![]() |
Check the operation.
Apply battery voltage to the rear door lock and check the operation of the door lock motor.
- Standard:
Measurement Condition
Specified Condition
Battery positive (+) → Terminal 2
Battery negative (-) → Terminal 1
Locks
Battery positive (+) → Terminal 1
Battery negative (-) → Terminal 2
Unlocks
Check the resistance of the position switch.
Using an ohmmeter, measure the resistance and check the results in accordance with the value(s) in the table below.
- Standard Resistance:
Tester Connection
Door Lock Condition
Specified Condition
5 - 6
Locked
10 kΩ or higher
5 - 6
Unlocked
Below 1 Ω
Check the operation of the double door lock motor.
Apply battery voltage to the rear door lock and check the operation of the double door lock motor.
- Standard:
Measurement Condition
Specified Condition
Battery positive (+) → Terminal 4
Battery negative (-) → Terminal 3
Set
Battery positive (+) → Terminal 3
Battery negative (-) → Terminal 4
Unset
While the double locking system is set, check that the doors cannot be unlocked by operating the control cable.
If the result is not as specified, replace the rear door lock.
Check the resistance of the double lock position switch.
Using an ohmmeter, measure the resistance and check the results in accordance with the value(s) in the table below.
- Standard Resistance:
Tester Connection
Door Lock Condition
Specified Condition
9 - 10
Set
Below 1 Ω
9 - 10
Unset
10 kΩ or higher
| INSPECT REAR DOOR LOCK ASSEMBLY LH (w/o Double Locking System) |
![]() ![]() |
Check the operation.
Apply battery voltage to the rear door lock and check the operation of the door lock motor.
- Standard:
Measurement Condition
Specified Condition
Battery positive (+) → Terminal 4
Battery negative (-) → Terminal 1
Locks
Battery positive (+) → Terminal 1
Battery negative (-) → Terminal 4
Unlocks
| INSPECT REAR DOOR LOCK ASSEMBLY RH (w/ Double Locking System) |
![]() ![]() |
Check the operation.
Apply battery voltage to the rear door lock and check the operation of the door lock motor.
- Standard:
Measurement Condition
Specified Condition
Battery positive (+) → Terminal 4
Battery negative (-) → Terminal 3
Locks
Battery positive (+) → Terminal 3
Battery negative (-) → Terminal 4
Unlocks
Check the resistance of the position switch.
Using an ohmmeter, measure the resistance and check the results in accordance with the value(s) in the table below.
- Standard Resistance:
Tester Connection
Door Lock Condition
Specified Condition
9 - 10
Locked
10 kΩ or higher
9 - 10
Unlocked
Below 1 Ω
Check the operation of the double door lock motor.
Apply battery voltage to the rear door lock and check the operation of the double door lock motor.
- Standard:
Measurement Condition
Specified Condition
Battery positive (+) → Terminal 2
Battery negative (-) → Terminal 1
Set
Battery positive (+) → Terminal 1
Battery negative (-) → Terminal 2
Unset
While the double locking system is set, check that the doors cannot be unlocked by operating the control cable.
If the result is not as specified, replace the rear door lock.
Check the resistance of the double lock position switch.
Using an ohmmeter, measure the resistance and check the results in accordance with the value(s) in the table below.- Standard Resistance:
Tester Connection
Door Lock Condition
Specified Condition
5 - 6
Set
Below 1 Ω
5 - 6
Unset
10 kΩ or higher
| INSPECT REAR DOOR LOCK ASSEMBLY RH (w/o Double Locking System) |
![]() ![]() |
Check the operation.
Apply battery voltage to the rear door lock and check the operation of the door lock motor.
- Standard:
Measurement Condition
Specified Condition
Battery positive (+) → Terminal 4
Battery negative (-) → Terminal 1
Locks
Battery positive (+) → Terminal 1
Battery negative (-) → Terminal 4
Unlocks