Malfunction in Water Temperature Warning Light
Circuit diagnosis · Vehicles built from Aug 2005
DESCRIPTION
The combination meter assembly controls the engine coolant temperature warning light in accordance with engine coolant temperature signals from the ECM through the CAM communication system.WIRING DIAGRAM


INSPECTION PROCEDURE
- HINT:
- If DTC U0100 has been stored, troubleshoot the CAN communication system first.
- If there is an open or short in the engine coolant temperature sensor circuit, an SFI system DTC is output. If output, perform troubleshooting on the SFI system related first.
- If DTC U0100 has been stored, troubleshoot the CAN communication system first.
| 1. PERFORM ACTIVE TEST USING INTELLIGENT TESTER (WATER TEMPERATURE METER) |
Connect the intelligent tester to the DLC3.
Turn the ignition switch on (IG) and turn the tester on.
Perform the Active Test according to the prompts displayed on the tester.
- Combination Meter:
Item
Test Details
Diagnostic Note
Indicat. Lamp Coolant Hot
Engine coolant temperature warning light (OFF / ON)
-
Indicat. Lamp Coolant Cool
Engine coolant temperature indicator light (OFF / ON)
-
Water Temperature Meter Operation
HIGH: Engine coolant temperature warning light flashes
NORMAL: Both engine coolant temperature warning light and indicator light turn off
LOW: Engine coolant temperature indicator light illuminates
-
- OK:
- Both the engine coolant temperature warning light and indicator light are operated in accordance with the tester instructions.
|
|
||||
| OK | |
| 2. READ VALUE USING INTELLIGENT TESTER (COOLANT TEMPERATURE) |
Connect the intelligent tester to the DLC3.
Turn the ignition switch on (IG) and turn the tester on.
Read the Data List according to the prompts displayed on the tester
- Combination Meter:
Item
Measurement Item / Range (Display)
Normal Condition
Diagnostic Note
Coolant Temperature
Engine coolant temperature / Min.: 0°C, MAX.: 127.5°C
After warming up: 75 to 105°C (167 to 221°F)
-
- OK:
- Engine coolant temperature displayed on the tester is between 75°C (167°F) and 105°C (221°F) after warming up.
- HINT:
- If the value is 0°C (32°F), the sensor circuit is open.
- If the value is 127.5°C (262°F), the sensor circuit is shorted.
|
|
||||
| OK | ||
| ||