2005-2008 Yaris · Service Manual HEATER & AIR CONDITIONING SYSTEM

TERMINALS OF ECU

System information · Vehicles built from Aug 2005


CHECK AIR CONDITIONING AMPLIFIER
*1: w/ PTC heater
If the result is not as specified, there may be a malfunction in the wire harness.
E115964E02

HINT:
Check from the rear of the connector while it is connected to the air conditioning amplifier.

Standard: 
Symbols (Terminals No.)
Wiring Color
Terminal Description
Condition
Specified Condition
B (E11-21) - GND (E11-14)
P - W-B
Power source (Back-up)
Always
10 to 14 V
SOL+ (E11-2) - GND (E11-14)
LG - W-B
A/C compressor operation signal
Engine idling
Pulse generation
(see waveform 1)
Blower switch: LO
A/C switch: ON
BLW (E11-23) - GND (E11-14)
R - W-B
Blower motor control signal
Ignition switch: on (IG)
Pulse generation
(see waveform 2)
Blower switch: LO
PRE (E11-9) - SG-2 (E11-13)
GR - B
Air conditioning pressure sensor signal
Refrigerant pressure: normal
0.76 to 4.74 V
PRE (E11-9) - SG-2 (E11-13)
GR - B
Air conditioning pressure sensor signal
Refrigerant pressure: Abnormal (less than 0.196 MPa [2.0 kgf/cm2]) or more than 3.14 MPa [32 kgf/cm2])
Below 0.76 V or 4.74 V or more
TS (E11-33) - S5-1 (E11-30)
R - L
Passenger side solar sensor signal
Ignition switch: on (IG)
0.8 to 4.3 V
Solar sensor subject to electric light
TR (E11-29) - SG-1 (E11-34)
V - SB
Room temperature sensor signal
Ignition switch: on (IG)
1.8 to 2.2 V
Vehicle interior temperature: 25°C
SG-1 (E11-34) - Body ground
SB - Body ground
Ground for room temperature sensor
Always
Below 1.0 Ω
GND (E11-14) - Body ground
W-B - Body ground
Ground for main power supply
Always
Below 1.0 Ω
IG+ (E11-1) - GND (E11-14)
Y - W-B
Power source (IG)
Ignition switch: on (IG)
10 to 14 V
S5-3 (E11-10) - GND (E11-14)
Y - W-B
Power supply for pressure sensor
Ignition switch: on (IG)
4.5 to 5.5 V
TX+ (E11-11) - GND(E11-14)
V - W-B
Hi-level CAN bus line
Ignition switch: on (IG)
Pulse generation
(see waveform 3)
TX- (E11-12) - GND (E11-14)
W - W-B
Lo-level CAN bus line
Ignition switch: on (IG)
Pulse generation
(see waveform 4)
SG-2 (E11-13) - Body ground
B - Body ground
Ground for pressure sensor
Always
Below 1.0 Ω
PTC1 (E11-3)*1 - Body ground
V - Body ground
PTC heater relay operation signal
Engine idling
Below 1 V → 10 to 14 V
Set temperature: MAX HOT
Engine coolant temperature: Below 65°C (149°F)
Ambient temperature: Below 10°C (50°F)
Blower switch: OFF → LO
PTC2 (E11-22)*1 - Body ground
BR - Body ground
PTC heater relay operation signal
Engine idling
Below 1 V → 10 to 14 V
Set temperature: MAX HOT
Engine coolant temperature: Below 65°C (149°F)
Ambient temperature: Below 10°C (50°F)
Blower switch: OFF → LO
PTC3 (E11-4)*1 - Body ground
R - Body ground
PTC heater relay operation signal
Engine idling
Below 1 V → 10 to 14 V
Set temperature: MAX HOT
Engine coolant temperature: Below 65°C (149°F)
Ambient temperature: Below 10°C (50°F)
Blower switch: OFF → LO
ALT (E11-25)*1 - Body ground
P - Body ground
Generator signal
Engine idling
Pulse generation
HLS (E11-27)*1 - Body ground
LG - Body ground
Head light signal
Engine idling
Below 1.0 Ω
Head light switch: ON
LIN1 (E11-37) - GND (E11-14)
LG - W-B
LIN communication signal
Ignition switch: on (IG)
Pulse generation
BUS G (T1-2) - Body ground
-
Ground for BUS IC
Always
Below 1.0 Ω
BUS (T1-3) - BUS G (T1-2)
-
BUS IC control signal
Ignition switch: on (IG)
Pulse generation
B BUS (T1-4) - BUS G (T1-2)
-
Power supply for BUS IC
Always
11 to 13 V
SG (T1-5) - Body ground
-
Ground for evaporator temperature sensor
Always
Below 1.0 Ω
TE (T1-6) - SG (T1-5)
-
Evaporator temperature sensor signal
Ignition switch: on (IG)
1.4 to 1.8 V
Evaporator temperature: 15°C (59°F)

  1. E074977E09
    Waveform 1 (Reference) : Using an oscilloscope
    Compressor and pulley operation signal 
    Terminal Name
    Between SOL+ (E11-2) - GND (E11-14)
    Tester Range
    5V/DIV, 500μs/DIV
    Condition
    Engine idling, Blower switch LO, A/C switch ON

  2. E103396E04
    Waveform 2 (Reference) : Using an oscilloscope.
    Blower motor control signal 
    Terminal Name
    Between BLW (E11-23) - GND (E11-14)
    Tester Range
    1V/DIV, 500μs/DIV
    Condition
    Ignition switch on (IG), Blower switch 1

    HINT:
    When the blower level is increased, the duty ratio changes accordingly.

  3. A086154E01
    Waveform 3 (Reference) : Using an oscilloscope
    CAN communication signal 
    Terminal Name
    Between TX+ (E11-11) - GND (E11-14)
    Tester Range
    1V/DIV, 10μs/DIV
    Condition
    Ignition switch on (IG)

    HINT:
    The waveform varies depending on the CAN communication signal.

  4. A086155E06
    Waveform 4 (Reference) : Using an oscilloscope
    CAN communication signal 
    Terminal Name
    Between TX- (E11-12) - GND (E11-14)
    Tester Range
    1V/DIV, 10μs/DIV
    Condition
    Ignition switch on (IG)

    HINT:
    The waveform varies depending on the CAN communication signal.


CHECK AIR CONDITIONING CONTROL
If the result is not as specified, there may be a malfunction in the wire harness.
E115965E01
Symbols (Terminals No.)
Wiring Color
Terminal Description
Condition
Specified Condition
IG (E16-5) - GND (E16-2)
V - W-B
Power source (IG)
Ignition switch: on (IG)
10 to 14 V
GND (E16-2) - Body ground
W-B - Body Ground
Ground for air conditioning control assembly
Always
Below 1.0 Ω
LIN1 (E16-3) - GND (E16-2)
LG - W-B
LIN communication signal
Ignition switch: on (IG)
Pulse generation