INSTALLATION
Removal / installation · Vehicles built from Aug 2005
| 1. INSTALL GENERATOR ASSEMBLY |
![]() ![]() |
Provisionally install the generator with fixing bolt B.
Provisionally install the fan belt adjusting slider with fan belt adjusting slider fixing bolts A and B, then move the generator toward the cylinder block and tighten bolt B.

- Torque:
- 34 N*m{ 347 kgf*cm , 25 ft.*lbf }
Install the connector and 2 wire harness clamps.

Install terminal B with the nut.
- Torque:
- 9.8 N*m{ 100 kgf*cm , 7 ft.*lbf }
Install the terminal cap.
| 2. INSTALL FAN AND GENERATOR V BELT |
![]() ![]() |
Install the fan and generator V belt.
Gently tighten bolt B until there is no measurable clearance.
Turn bolt C to adjust the tension of the fan and generator V belt.
Inspect the fan and generator V belt.
Tighten bolt B.
- Torque:
- 34 N*m{ 347 kgf*cm , 25 ft.*lbf }
Tighten bolt A.
- Torque:
- 54 N*m{ 551 kgf*cm , 40 ft.*lbf }
Visually check the generator wiring and listen for abnormal noise.
Check that the wiring is in good condition.
Check that there is no abnormal noise from the generator while the engine is running.
Inspect the discharge warning light circuit.

Turn the ignition switch to the ON position. Check that the discharge warning light illuminates.
Start the engine. Check that the light goes off.
| 3. INSPECT FAN AND GENERATOR V BELT |
![]() ![]() |
Visually check the belt for excessive wear, frayed cords etc.
If any defect is found, replace the belt.- HINT:
- Cracks on the rib side of a belt are considered acceptable. If the belt has pieces missing from the ribs, it should be replaced.
| 4. CONNECT CABLE TO NEGATIVE BATTERY TERMINAL |
- Torque: