P0741 Torque Converter Clutch Solenoid Performance (Shift Solenoid Valve SL)
Diagnostic trouble codes · Vehicles built from Aug 2005
DESCRIPTION
The ECM uses the signals from the throttle position sensor, mass air flow meter and crankshaft position sensor to monitor the engagement condition of the lock-up clutch.Then the ECM compares the engagement condition of the lock-up clutch with the lock-up schedule in the ECM memory to detect mechanical problems of the shift solenoid valve SL, valve body and torque converter transaxle (clutch, brake or gear etc.).
| DTC No. |
DTC Detection Condition |
Trouble Area |
| P0741 |
(a) Lock-up does not occur when driving in lock-up range or lock-up remains ON in lock-up OFF range. (2-trip detection logic) (b) When lock-up is ON, clutch or brake slippage occurs or gear breaks. (2-trip detection logic) |
|
MONITOR DESCRIPTION
Torque converter lock-up is controlled by the ECM based on the speed sensor (NT), engine rpm (NE), engine load, engine temperature, vehicle speed, transmission fluid temperature, and gear selection. The ECM determines the lock-up status of the torque converter by comparing the engine rpm (NE) to the input turbine rpm (NT). The ECM calculates the actual transmission gear by comparing input turbine rpm (NT) to output shaft speed. When conditions are appropriate, the ECM requests lock-up by applying the control voltage to the shift solenoid SL. When the SL is turned on, it applies pressure to the lock-up relay valve and locks the torque converter clutch.If the ECM detects no lock-up after lock-up has been requested or if it detects lock-up when it has not been requested, the ECM interprets this as a fault in the shift solenoid valve SL or lock-up system performance. The ECM turns on the MIL and stores the DTC.
INSPECTION PROCEDURE
| ACTIVE TEST |
- HINT:
- Performing the Active Test using the intelligent tester allows components, such as the relay, VSV, and actuator, to be operated without removing any parts. Performing the Active Test as the first step of troubleshooting is one method of shortening labor time.
- It is possible to display the Data List during the Active Test.
Warm up the engine.
Turn the ignition switch off.
Connect the intelligent tester to the DLC3.
Turn the ignition switch on (IG).
Turn on the tester
Select the following items: Powertrain / Engine and ECT / Active Test / Control the Lock Up.
In accordance with the display on the tester, perform the Active Test.
Item
Test Details
Diagnostic Note
Control the Lock Up
[Test Details]
Control the shift solenoid SL to set automatic transaxle to lock-up condition.
[Vehicle Condition]
Vehicle Speed: 60 km/h (36 mph) or more, and 4th gear
Possible to check SL operation.
- HINT:
- This test can be conducted when the vehicle speed is 60 km/h (36 mph) or more.
- This test can be conducted in 4th gear.
- This test can be conducted when the vehicle speed is 60 km/h (36 mph) or more.
Lightly depress the accelerator pedal and check that the engine speed does not change abruptly.


- HINT:
- When changing the accelerator pedal opening angle while driving, if the engine speed does not change, lock-up is on.
- Slowly, but not fully, release the accelerator pedal in order to decelerate. (Fully releasing the pedal will close the throttle valve and lock-up may be turned off.)
- When changing the accelerator pedal opening angle while driving, if the engine speed does not change, lock-up is on.
| 1. CHECK OTHER DTCS OUTPUT (IN ADDITION TO DTC P0741) |
Connect the intelligent tester to the DLC3.
Turn the ignition switch on (IG).
Turn on the tester.
Select the following items: Powertrain / Engine and ECT / DTC / Current or Pending.
Read the DTCs using the tester.
- Result:
Display (DTC output)
Proceed to
P0741
A
P0741 and other DTCs
B
- HINT:
- If any other DTCs besides P0741 are output, perform troubleshooting for those DTCs first.
|
|
||||
| A | |
| 2. INSPECT SHIFT SOLENOID VALVE SL |
![]() ![]() |
Remove shift solenoid valve SL.
Measure the resistance.
- Standard resistance:
Tester Connection
Specified Condition
Solenoid Connector (SL) - Solenoid Body (SL)
11 to 15 Ωat 20°C (68°F)
Connect the positive (+) lead to the terminal of the solenoid connector and the negative (-) lead to the solenoid body to check the solenoid valve operation.
- OK:
- The solenoid makes operating sounds.
|
|
||||
| OK | |
| 3. INSPECT TRANSMISSION VALVE BODY ASSEMBLY |
- OK:
- There are no foreign objects on any valves and they operate smoothly.
|
|
||||
| OK | |
| 4. INSPECT TORQUE CONVERTER CLUTCH ASSEMBLY |
- OK:
- The torque converter clutch operates normally.
|
|
||||
| OK | ||
| ||