INSPECTION
Inspection · Vehicles built from Nov 2006
| INSPECT ACC CUT RELAY |
![]() ![]() |
Check the resistance.
Using an ohmmeter, measure the resistance between the terminals.
- Standard resistance:
Tester Connection
Specified Condition
3 - 4
Below 1 Ω
10 kΩ or higher (when battery voltage applied to terminals 1 and 2)
3 - 5
Below 1 Ω (when battery voltage applied to terminals 1 and 2)
10 kΩ or higher