2005-2008 Yaris · Service Manual SERVICE SPECIFICATIONS

SERVICE DATA

Specifications · Vehicles built from Aug 2005

PTC heater assembly
1 - 2 : Below 1Ω
2 - 3 : Below 1Ω
1 - 3 : Below 1Ω
Blower resistor
1 - 4 : 3.12 to 3.60 Ω
3 - 4 : 1.45 to 1.67 Ω
2 - 4 : 0.52 to 0.60 Ω
Compressor and pulley
10.1 to 11.1 Ω at 25 °C (77°F)
Heater blower motor relay
3 - 4 : Below 1Ω
3 - 4 : 10kΩ or higher (Apply battery voltage to terminals 1 and 2)
3 - 5 : 10kΩ or higher
3 - 5 : Below 1Ω(Apply battery voltage to terminals 1 and 2)
PTC heater relay
3 - 5 : 10kΩ or higher
3 - 5 : Below 1Ω(Apply battery voltage to terminals 1 and 2)
for 1KR-FE 
Idling speed
Switch A/C OFF
730 to 830 rpm
Idling speed
Switch A/C ON
750 to 850 rpm
for 1NZ-FE manual transaxle and 2NZ-FE manual transaxle 
Idling speed
Switch A/C OFF
600 to 700 rpm
Idling speed
Switch A/C ON (A/C Lo → Hi)
700 → 850 rpm
for 1NZ-FE automatic transaxle and 2NZ-FE automatic transaxle 
Idling speed
Switch A/C OFF
650 to 750 rpm
Idling speed
Switch A/C ON (A/C Lo → Hi)
700 → 850 rpm
for 2ZR-FE 
Idling speed
Switch A/C OFF
600 to 700 rpm
Idling speed
Switch A/C ON (A/C Lo → Hi)
700 → 850 rpm
for 2SZ-FE 
Idling speed
Switch A/C OFF
550 to 650 rpm
Idling speed
Switch A/C ON (A/C Lo → Hi)
700 → 850 rpm
for 1ND-TV 
Idling speed
Switch A/C OFF
720 to 820 rpm
Idling speed
Switch A/C ON
800 to 900 rpm
w/o Fan Shroud Ventilation Duct: 
Refrigerant charge volume
330 to 390 g (11.64 to 13.76 oz.)
w/ Fan Shroud Ventilation Duct: 
Refrigerant charge volume
350 to 410 g (12.35 to 14.46 oz.)
← TORQUE SPECIFICATIONS (from Aug 2005)TORQUE SPECIFICATIONS (from Aug 2005) →