INSTALLATION
Removal / installation · Vehicles built from Nov 2005
| 1. INSTALL FAN AND GENERATOR V BELT |
Provisionally install the V belt onto the pulleys.
| 2. INSTALL TRANSVERSE ENGINE ENGINE MOUNTING INSULATOR |
![]() ![]() |
Operate the jack and Install the insulator with the 5 bolts and nut.
- Torque:
- 52 N*m{ 530 kgf*cm , 38 ft.*lbf }
Install the low pressure pipe stay of the air conditioner with the bolt.

- Torque:
- 10 N*m{ 100 kgf*cm , 7 ft.*lbf }
| 3. ADJUST FAN AND GENERATOR V BELT |
![]() ![]() |
Turn adjusting bolt C and adjust the tension of the V-belt.
Tighten fixing bolts A and B.
- Torque:
- 19 N*m{ 194 kgf*cm , 14 ft.*lbf } bolt A
- 44 N*m{ 449 kgf*cm , 33 ft.*lbf } bolt B
| 4. INSPECT FAN AND GENERATOR V BELT |
![]() ![]() |
Check the V belt deflection and tension.
- Deflection:
Item
Specified Condition
New belt
7.0 to 8.0 mm (0.28 to 0.31 in) w/ air conditioning system
4.0 to 5.0 mm (0.16 to 0.20 in) w/o air conditioning system
Used belt
9.0 to 9.5 mm (0.35 to 0.37 in) w/ air conditioning system
6.0 to 6.5 mm (0.24 to 0.26 in) w/o air conditioning system
- Tension:
Item
Specified Condition
New belt
687 to 883 N (70 to 90 kg, 154 to 199 ld) w/ air conditioning system
785 to 981 N (80 to 100 kg, 176 to 221 ld) w/o air conditioning system
Used belt
539 to 637 N (55 to 65 kg, 121 to 143 ld)
- HINT:
- Check the V belt deflection at the specified point.
- When installing a new belt, set its tension to the specified value.
- When inspecting a belt which has been used for over 5 minutes, apply the Used Belt specifications.
- When reinstalling a belt which has been used for over 5 minutes, adjust its deflection and tension to the intermediate values of each Used Belt specification.
- V-ribbed belt tension and deflection should be checked after 2 revolutions of engine cranking.
- When using a belt tension gauge, confirm its accuracy by using a master gauge first.
- Check the V belt deflection at the specified point.
| 5. INSTALL ENGINE UNDER COVER RH |