Check the operation. Make sure that the sprocket turns freely. If necessary, replace the oil pump assembly.
Check the tip clearance. Using a feeler gauge, measure the clearance between the drive and driven rotor tips.
Standard tip clearance:
0.08 to 0.15 mm (0.0031 to 0.0059 in.)
Maximum tip clearance:
0.2 mm (0.0079 in.)
If the tip clearance is greater than the maximum, replace the oil pump assembly.
Check the body clearance. Using a feeler gauge, measure the clearance between the driven rotor and body.
Standard body clearance:
0.155 to 0.265 mm (0.0061 to 0.0104 in.)
Maximum body clearance:
0.3 mm (0.0118 in.)
If the body clearance is greater than the maximum, replace the oil pump assembly.
Check the side clearance. Using a feeler gauge and precision straight edge, measure the clearance between the driven rotor and precision straight edge.
Standard side clearance:
0.03 to 0.08 mm (0.0012 to 0.0031 in.)
Maximum side clearance:
0.1 mm (0.0039 in.)
If the side clearance is greater than the maximum, replace the oil pump assembly.