ON-VEHICLE INSPECTION
Inspection · Vehicles built from Nov 2005
| INSPECT GLOW PLUG RELAY ASSEMBLY |
![]() ![]() |
Check the resistance.
Using an ohmmeter, measure the resistance between the terminals.
- Standard resistance:
Tester Connection
Specified Condition
1 - 2
10 kΩ or higher
1 - 2
Below 1 Ω
(Apply battery voltage between terminals 3 and 4)