SERVICE DATA
Specifications · Vehicles built from Nov 2005
| Grow plug |
Standard Resistance |
0.6 Ω at 20°C (68°F) |
| Starter assembly |
Standard current |
90 A or less at 11.5 V |
| Starter relay |
Standard resistance 3 - 5 |
Below 1 Ω (when battery voltage applied to terminals 1 and 2) |
| 10 kΩ or higher | ||
| Starter cut relay (w/ Entry and Start System) |
Standard resistance 3 - 5 |
Below 1 Ω (when battery voltage applied to terminals 1 and 2) |
| 10 kΩ or higher | ||
| ACC relay (w/ Entry and Start System) |
Standard resistance 3 - 4 |
Below 1 Ω |
| 10 kΩ or higher (when battery voltage applied to terminals 1 and 2) | ||
| Standard resistance 3 - 5 |
Below 1 Ω (when battery voltage applied to terminals 1 and 2) |
|
| 10 k Ω or higher | ||
| ACC cut relay (w/o Entry and Start System) |
Standard resistance 3 - 4 |
Below 1 Ω |
| 10 kΩ or higher (when battery voltage applied to terminals 1 and 2) | ||
| Standard resistance 3 - 5 |
Below 1 Ω(when battery voltage applied to terminals 1 and 2) |
|
| 10 kΩ or higher | ||
| AM2 fuse |
Standard resistance 1 - 2 |
Below 1 Ω |
| IG2 relay |
Standard resistance B1 - C1 |
Below 1 Ω |
| Standard resistance B1 - B4 |
10 kΩ or higher |
|
| Standard resistance B4 - C1 |
10 kΩ or higher |
|
| Standard resistance B1 - B4 |
Below 1 Ω (Apply battery voltage between terminals B2 and B3) |
|
| Standard resistance B4 - C1 |
Below 1 Ω (Apply battery voltage between terminals B2 and B3) |
|
| Engine switch (w/ Entry and Start System) |
Standard resistance 7 - 5 |
10 kΩ or higher (Released) |
| Below 1 Ω (Pushed) | ||
| Standard resistance 2 - 5 |
10 kΩ or higher (Released) |
|
| Below 1 Ω (Pushed) | ||
| Ignition relay |
Standard resistance 3 - 5 |
Below 1 Ω(when battery voltage applied to terminals 1 and 2) |
| 10 kΩ or higher | ||
| Ignition or starter switch assembly (w/o Entry and Start System) |
Standard resistance Between all terminals |
10 kΩ or higher (LOCK) |
| Standard resistance 2-4 |
Below 1 Ω (ACC) |
|
| Standard resistance 1-2-4 |
Below 1 Ω (ON) |
|
| Standard resistance 5-6 | ||
| Standard resistance 1-3-4 |
Below 1 Ω (START) |
|
| Standard resistance 5-6-7 | ||
| Starter armature assembly resistance |
Segments |
Below 1Ω |
| Commutator-Armature coil |
10kΩ or higher |
|
| Starter armature assembly commutator cirumference runout |
Standard runout |
0.02mm (0.0008in.) |
| Maximum runout |
0.04mm (0.0016in.) |
|
| Starter armature assembly commutator diameter |
Standard diameter |
29.9mm (1.1772 in.) |
| Minimum diameter |
28.8mm (1.1339 in.) |
|
| Starter armature assembly undercut depth |
Standard depth |
0.9mm (0.00354 in.) |
| Minimum depth |
0.4mm (0.0157 in.) |
|
| Starter brush holder assembly Brush length |
Standard length |
10.5mm (0.4134 in.) |
| Minimum length |
7.0mm (0.2756 in.) |
|
| Starter brush holder assembly resistance |
A-B |
10kΩor higher |
| A-C |
10kΩor higher |
|
| A-D |
Below 1 Ω |
|
| B-C |
Below 1 Ω |
|
| B-D |
10kΩor higher |
|
| C-D |
10kΩor higher |
|
| Magnet starter switch assembly resistance |
Terminal C-Terminal l 50 |
Below 1Ω |
| Terminal 50-Magnet starter switch assembly |
Below 1.5Ω |
| Grow plug |
Standard Resistance |
0.6 Ω at 20°C (68°F) |
| Starter assembly |
Standard current |
100 A or less at 11.5 V |
| Starter relay |
Standard resistance 3 - 5 |
Below 1 Ω (when battery voltage applied to terminals 1 and 2) |
| 10 kΩ or higher | ||
| Starter cut relay (w/ Entry and Start System) |
Standard resistance 3 - 5 |
Below 1 Ω (when battery voltage applied to terminals 1 and 2) |
| 10 kΩ or higher | ||
| ACC relay (w/ Entry and Start System) |
Standard resistance 3 - 4 |
Below 1 Ω |
| 10 kΩ or higher (when battery voltage applied to terminals 1 and 2) | ||
| Standard resistance 3 - 5 |
Below 1 Ω (when battery voltage applied to terminals 1 and 2) |
|
| 10 k Ω or higher | ||
| ACC cut relay (w/o Entry and Start System) |
Standard resistance 3 - 4 |
Below 1 Ω |
| 10 kΩ or higher (when battery voltage applied to terminals 1 and 2) | ||
| Standard resistance 3 - 5 |
Below 1 Ω(when battery voltage applied to terminals 1 and 2) |
|
| 10 kΩ or higher | ||
| AM2 fuse |
Standard resistance 1 - 2 |
Below 1 Ω |
| IG2 relay |
Standard resistance B1 - C1 |
Below 1 Ω |
| Standard resistance B1 - B4 |
10 kΩ or higher |
|
| Standard resistance B4 - C1 |
10 kΩ or higher |
|
| Standard resistance B1 - B4 |
Below 1 Ω (Apply battery voltage between terminals B2 and B3) |
|
| Standard resistance B4 - C1 |
Below 1 Ω (Apply battery voltage between terminals B2 and B3) |
|
| Engine switch (w/ Entry and Start System) |
Standard resistance 7 - 5 |
10 kΩ or higher (Released) |
| Below 1 Ω (Pushed) | ||
| Standard resistance 2 - 5 |
10 kΩ or higher (Released) |
|
| Below 1 Ω (Pushed) | ||
| Ignition relay |
Standard resistance 3 - 5 |
Below 1 Ω(when battery voltage applied to terminals 1 and 2) |
| 10 kΩ or higher | ||
| Ignition or starter switch assembly (w/o Entry and Start System) |
Standard resistance Between all terminals |
10 kΩ or higher (LOCK) |
| Standard resistance 2-4 |
Below 1 Ω (ACC) |
|
| Standard resistance 1-2-4 |
Below 1 Ω (ON) |
|
| Standard resistance 5-6 | ||
| Standard resistance 1-3-4 |
Below 1 Ω (START) |
|
| Standard resistance 5-6-7 | ||
| Starter yoke assembly |
Standard resistance Lead wire-Brush lead |
1Ω or less |
| Standard resistance Lead wire-Body |
10kΩ or higher |
|
| Starter yoke assembly brush length |
Standard length |
15.0mm (0.591in.) |
| Minimum length |
9.0mm (0.354in.) |
|
| Starter armature assembly resistance |
Segments |
1Ω or less |
| Commutator-Armature coil |
10kΩ or higher |
|
| Starter armature assembly commutator diameter |
Standard diameter |
35mm (1.378 in.) |
| Minimum diameter |
34mm (1.339 in.) |
|
| Starter armature assembly undercut depth |
Standard depth |
0.7mm (0.028 in.) |
| Minimum depth |
0.2mm (0.008 in.) |
|
| Starter brush holder assembly Brush length |
Standard length |
15.0mm (0.591 in.) |
| Minimum length |
9.0mm (0.354 in.) |
|
| Starter brush holder assembly Brush spring load |
Standard load |
21.5 to 27.5 N (2.2 to 2.8 kgf, 4.9 to 6.2 ldf) |
| Minimum load |
12.7N (1.3 kgf, 2.9 ldf) |
|
| Starter brush holder assembly resistance |
Standard resistance |
10kΩor higher |
| Magnet starter switch assembly resistance |
Terminal C-Terminal l 50 |
1Ω or less |
| Terminal 50-Magnet starter switch assembly |
1Ω or less |