COMPRESSOR AND PULLEY (for 1NZ-FE, 2NZ-FE) > INSTALLATION |
| 1. ADJUST COMPRESSOR OIL |
![]() |
When replacing the compressor with a new one, gradually discharge the refrigerant gas from the service valve. Then drain the following amount of oil from the new compressor before installation, so that the amount of oil contained in it is the same as that in the compressor to be replaced.
| 2. INSTALL COMPRESSOR AND PULLEY |
![]() |
Provisionally tighten the compressor with the bolt.
![]() |
Tighten the compressor with the 4 bolts.
Connect the connector and the clamp.
| 3. INSTALL NO. 1 COOLER REFRIGERANT DISCHARGE HOSE |
![]() |
Remove the attached vinyl tape from the hose.
Apply sufficient compressor oil (ND-OIL8) to a new O-ring and the fitting surface of the compressor.
Install the O-ring onto the discharge hose.
Install the discharge hose onto the compressor with the bolt.
| 4. INSTALL NO. 1 COOLER REFRIGERANT SUCTION HOSE |
![]() |
Remove the attached vinyl tape from the hose.
Apply sufficient compressor oil (ND-OIL8) to a new O-ring and the fitting surface of the compressor.
Install the O-ring onto the suction hose.
Install the suction hose onto the compressor with the bolt.
| 5. INSTALL FAN & GENERATOR V BELT (for 1NZ-FE) |
Provisionally install the fan and generator V belt onto each pulley.
| 6. INSTALL FAN & GENERATOR V BELT (for 2NZ-FE) |
Provisionally install the fan and generator V belt onto each pulley.
| 7. ADJUST FAN & GENERATOR V BELT (for 1NZ-FE) |
![]() |
Insert an adjusting bar between the engine mounting bracket and generator assembly. Pull the adjusting bar towards the vehicle front to adjust the generator V belt tension.
![]() |
First tighten bolt A, then tighten bolt B.
| 8. ADJUST FAN & GENERATOR V BELT (for 2NZ-FE) |
![]() |
for Unleaded Gasoline Specification Vehicle:
Insert an adjusting bar between the engine mounting bracket and generator assembly. Pull the adjusting bar towards the vehicle front to adjust the generator V belt tension.
![]() |
for Leaded Gasoline Specification Vehicle:
Insert the adjusting bar between the engine mounting bracket and generator assembly. Pull the adjusting bar towards the vehicle front to adjust the generator V belt tension.
![]() |
First tighten bolt A, then tighten bolt B.
| 9. INSPECT FAN & GENERATOR V BELT (for 1NZ-FE) |
![]() |
Check the V belt deflection and tension.
| Item | Specified Condition |
| New belt | 8.0 to 9.0 mm (0.31 to 0.35 in) |
| Used belt | 12.5 to 13.5 mm (0.49 to 0.53 in) |
| Item | Specified Condition |
| New belt | 700 to 800 N (71 to 82 kg, 157 to 180 lb) |
| Used belt | 300 to 400 N (31 to 41 kg, 67 to 90 lb) |
| 10. INSPECT FAN & GENERATOR V BELT (for 2NZ-FE) |
![]() |
Check the V belt deflection and tension.
| Item | Specified Condition |
| New belt | 8.0 to 9.0 mm (0.31 to 0.35 in) |
| Used belt | 12.5 to 13.5 mm (0.49 to 0.53 in) |
| Item | Specified Condition |
| New belt | 700 to 800 N (71 to 82 kg, 157 to 180 lb) |
| Used belt | 300 to 400 N (31 to 41 kg, 67 to 90 lb) |
| 11. CHARGE REFRIGERANT |

Perform vacuum purging using a vacuum pump.
Charge refrigerant HFC-134a (R134a).

Install the caps onto the service valves on the refrigerant line.
| 12. WARM UP ENGINE |
| 13. CHECK FOR REFRIGERANT LEAKAGE |
After recharging the refrigerant gas, check for refrigerant gas leakage using a halogen leak detector.
Perform the operation as follows:
![]() |
Using the halogen leak detector, check the refrigerant line, especially at the connection points, for leakage.
![]() |
Bring the halogen leak detector close to the drain hose before performing the test.
If no gas leakage is detected from the drain hose, remove the blower motor from the cooling unit. Insert the halogen leak detector sensor into the unit and perform the test.
Disconnect the pressure switch connector and leave it for approximately 20 minutes. Bring the halogen leak detector close to the pressure switch and perform the test.
| 14. INSTALL ENGINE UNDER COVER RH |
| 15. INSTALL ENGINE UNDER COVER SUB-ASSEMBLY (for Rough Road Area Specification Vehicles) |