Home › HEATER & AIR CONDITIONING SYSTEM › AIR CONDITIONING › COMPRESSOR AND PULLEY (for 1NZ-FE, 2NZ-FE)

COMPRESSOR AND PULLEY (for 1NZ-FE, 2NZ-FE) > INSTALLATION

for Preparation Click here



1. ADJUST COMPRESSOR OIL


I101566E01
  1. When replacing the compressor with a new one, gradually discharge the refrigerant gas from the service valve. Then drain the following amount of oil from the new compressor before installation, so that the amount of oil contained in it is the same as that in the compressor to be replaced.

    HINT:
    New compressors are filled with sufficient oil for the whole cycle. Therefore, it is necessary to drain residual oil from the condenser and cooling unit.

    Standard:
    (The amount of oil inside a new compressor: 60 (+15) cc (2.0 (+0.51) fl.oz.)) - (The amount of oil remaining in the removed compressor) = The amount of oil to be removed when replacing the compressor

    NOTICE:
    1. When checking the compressor oil level, observe the precautions for cooler removal/installation.
    2. If a new compressor is installed without removing the amount of oil remaining in the pipes of the vehicle, the amount of oil becomes too large. This prevents heat exchange in the refrigerant cycle and causes refrigeration failure.
    3. If the amount of oil remaining in the removed compressor is too small, check for oil leakage.
    4. Use ND-OIL8 compressor oil.



2. INSTALL COMPRESSOR AND PULLEY


I101226
  1. Provisionally tighten the compressor with the bolt.



    I101227E01
  1. Tighten the compressor with the 4 bolts.

    Torque:
    25 N*m{ 255 kgf*cm , 18 ft.*lbf }

    NOTICE:
    Tighten the bolts in the sequence order shown in the illustration to install the compressor.

  1. Connect the connector and the clamp.



3. INSTALL NO. 1 COOLER REFRIGERANT DISCHARGE HOSE


I101565
  1. Remove the attached vinyl tape from the hose.

  1. Apply sufficient compressor oil (ND-OIL8) to a new O-ring and the fitting surface of the compressor.

    Compressor oil:
    ND-OIL8 or the equivalent

  1. Install the O-ring onto the discharge hose.

  1. Install the discharge hose onto the compressor with the bolt.

    Torque:
    9.8 N*m{ 100 kgf*cm , 87 in.*lbf }



4. INSTALL NO. 1 COOLER REFRIGERANT SUCTION HOSE


I101564
  1. Remove the attached vinyl tape from the hose.

  1. Apply sufficient compressor oil (ND-OIL8) to a new O-ring and the fitting surface of the compressor.

    Compressor oil:
    ND-OIL8 or the equivalent

  1. Install the O-ring onto the suction hose.

  1. Install the suction hose onto the compressor with the bolt.

    Torque:
    9.8 N*m{ 100 kgf*cm , 87 in.*lbf }



5. INSTALL FAN & GENERATOR V BELT (for 1NZ-FE)
  1. Provisionally install the fan and generator V belt onto each pulley.

    NOTICE:
    1. Make sure that there is no foreign matter or liquid, such as oil, on the belt and pulleys.
    2. Make sure that the V belt is securely fitted into the rib grooves of the pulley.



6. INSTALL FAN & GENERATOR V BELT (for 2NZ-FE)
  1. Provisionally install the fan and generator V belt onto each pulley.

    NOTICE:
    1. Make sure that there is no foreign matter or liquid, such as oil, on the belt and pulleys.
    2. Make sure that the V belt is securely fitted into the rib grooves of the pulley.



7. ADJUST FAN & GENERATOR V BELT (for 1NZ-FE)


    A116198E01
  1. Insert an adjusting bar between the engine mounting bracket and generator assembly. Pull the adjusting bar towards the vehicle front to adjust the generator V belt tension.

    NOTICE:
    Do not insert the adjusting bar between the camshaft timing oil control valve assembly and generator assembly. It could damage the camshaft timing oil control valve assembly.



    A116197E01
  1. First tighten bolt A, then tighten bolt B.

    Torque:
    19 N*m{ 189 kgf*cm , 14 ft.*lbf } for bolt A
    54 N*m{ 551 kgf*cm , 40 ft.*lbf } for bolt B



8. ADJUST FAN & GENERATOR V BELT (for 2NZ-FE)


    A116198E01
  1. for Unleaded Gasoline Specification Vehicle:
    Insert an adjusting bar between the engine mounting bracket and generator assembly. Pull the adjusting bar towards the vehicle front to adjust the generator V belt tension.

    NOTICE:
    Do not insert the adjusting bar between the camshaft timing oil control valve assembly and generator assembly. It could damage the camshaft timing oil control valve assembly.



    A117470
  1. for Leaded Gasoline Specification Vehicle:
    Insert the adjusting bar between the engine mounting bracket and generator assembly. Pull the adjusting bar towards the vehicle front to adjust the generator V belt tension.



    A116197E01
  1. First tighten bolt A, then tighten bolt B.

    Torque:
    19 N*m{ 189 kgf*cm , 14 ft.*lbf } for bolt A
    54 N*m{ 551 kgf*cm , 40 ft.*lbf } for bolt B



9. INSPECT FAN & GENERATOR V BELT (for 1NZ-FE)


    A116200E01
  1. Check the V belt deflection and tension.

    Deflection:
    Item
    Specified Condition
    New belt
    8.0 to 9.0 mm (0.31 to 0.35 in)
    Used belt
    12.5 to 13.5 mm (0.49 to 0.53 in)

    Tension:
    Item
    Specified Condition
    New belt
    700 to 800 N (71 to 82 kg, 157 to 180 lb)
    Used belt
    300 to 400 N (31 to 41 kg, 67 to 90 lb)

    If the belt deflection is not as specified, adjust it.

    HINT:
    1. Perform the V belt inspection and adjustment while the engine is cold.
    2. V-ribbed belt tension and deflection should be checked immediately after installation of a new belt, and after cranking the engine when inspecting a used belt.
    3. Check the V belt deflection at the point between the specified pulleys where the deflection is greatest.
    4. When installing a new belt, set its tension to the intermediate value of the specification.
    5. When inspecting a belt which has been used for over 5 minutes, apply the Used Belt specifications.
    6. When reinstalling a belt which has been used for over 5 minutes, adjust its deflection and tension to the intermediate values of each Used Belt specification.
    7. V-ribbed belt tension and deflection should be checked after 2 revolutions of engine cranking.
    8. When using a belt tension gauge, confirm its accuracy by using a master gauge first.



10. INSPECT FAN & GENERATOR V BELT (for 2NZ-FE)


    A116200E01
  1. Check the V belt deflection and tension.

    Deflection:
    Item
    Specified Condition
    New belt
    8.0 to 9.0 mm (0.31 to 0.35 in)
    Used belt
    12.5 to 13.5 mm (0.49 to 0.53 in)

    Tension:
    Item
    Specified Condition
    New belt
    700 to 800 N (71 to 82 kg, 157 to 180 lb)
    Used belt
    300 to 400 N (31 to 41 kg, 67 to 90 lb)

    If the belt deflection is not as specified, adjust it.

    HINT:
    1. Perform the V belt inspection and adjustment while the engine is cold.
    2. V-ribbed belt tension and deflection should be checked immediately after installation of a new belt, and after cranking the engine when inspecting a used belt.
    3. Check the V belt deflection at the point between the specified pulleys where the deflection is greatest.
    4. When installing a new belt, set its tension to the intermediate value of the specification.
    5. When inspecting a belt which has been used for over 5 minutes, apply the Used Belt specifications.
    6. When reinstalling a belt which has been used for over 5 minutes, adjust its deflection and tension to the intermediate values of each Used Belt specification.
    7. V-ribbed belt tension and deflection should be checked after 2 revolutions of engine cranking.
    8. When using a belt tension gauge, confirm its accuracy by using a master gauge first.



11. CHARGE REFRIGERANT



I100449E02

NOTICE:
Charge refrigerant in accordance with the equipment manual.

  1. Perform vacuum purging using a vacuum pump.

  1. Charge refrigerant HFC-134a (R134a).

    SST
    09985-20010   (09985-02010, 09985-02050, 09985-02060, 09985-02070, 09985-02080, 09985-02090, 09985-02110, 09985-02130, 09985-02140, 09985-02150)

    Standard:
    330 to 390 g (11.64 to 13.76 oz.) w/o Fan Shroud Ventilation Duct
    350 to 410 g (12.35 to 14.46 oz.) w/ Fan Shroud Ventilation Duct

    NOTICE:
    Do not start the engine before charging it with refrigerant as the cooler compressor doesn't work properly without sufficient refrigerant. This could cause the compressor to overheat.

    HINT:

    1. The relationship between the refrigerant charge amount and the pressure is as follows.


      I101544E02

    2. High Charge Range:
      If the refrigerant is overcharged, the pressure rises on the high-pressure side. High-pressure cut off frequently occurs. This causes insufficient cooling performance and also insufficient compressor lubrication.
    3. Low Charge Range:
      Shortage of refrigerant causes insufficient cooling performance and low circulation of refrigerant oil, which shortens the compressor life. Operation with insufficient coolant raises the refrigerant temperature and causes heat deterioration of the rubber seals and hoses. Cracking and thus refrigerant leakage may occur.


    1. Install the caps onto the service valves on the refrigerant line.



12. WARM UP ENGINE

NOTICE:
Warm up the engine at less than 2000 rpm for 1 minute or more after charging it with refrigerant.



13. CHECK FOR REFRIGERANT LEAKAGE
  1. After recharging the refrigerant gas, check for refrigerant gas leakage using a halogen leak detector.

  1. Perform the operation as follows:

    1. Stop the engine.
    2. Secure good ventilation (the halogen leak detector may react to volatile gases other than refrigerant, such as evaporated gasoline or exhaust gas).
    3. Repeat the test 2 or 3 times.
    4. Make sure that some refrigerant remains in the refrigeration system.
      When the compressor is off: approximately 392 to 588 kPa (4 to 6 kgf*cm2, 57 to 85 psi)

    HINT:
    It is impossible for the above pressure to be maintained if there is leakage.



    I101569E02
  1. Using the halogen leak detector, check the refrigerant line, especially at the connection points, for leakage.



    I100587E02
  1. Bring the halogen leak detector close to the drain hose before performing the test.

    HINT:
    1. After the blower motor has stopped, leave the cooling unit for at least 15 minutes.
    2. Place the halogen leak detector sensor under the drain hose.
    3. When bringing the halogen leak detector close to the drain hose, make sure that the halogen leak detector does not react to the volatile gases.

    If such a reaction is unavoidable, the vehicle must be lifted up.

  1. If no gas leakage is detected from the drain hose, remove the blower motor from the cooling unit. Insert the halogen leak detector sensor into the unit and perform the test.

  1. Disconnect the pressure switch connector and leave it for approximately 20 minutes. Bring the halogen leak detector close to the pressure switch and perform the test.



14. INSTALL ENGINE UNDER COVER RH


15. INSTALL ENGINE UNDER COVER SUB-ASSEMBLY (for Rough Road Area Specification Vehicles)