POWER DOOR LOCK CONTROL SYSTEM > Only Rear Door RH LOCK / UNLOCK Functions do not Operate |

| 1.INSPECT REAR DOOR LOCK ASSEMBLY RH |
![]() |
LHD:
Apply the battery voltage to the door lock motor and check the operation of the door lock motor.
| Measurement Condition | Specified Condition |
| Battery positive (+) → Terminal 4 Battery negative (-) → Terminal 1 | Lock |
| Battery positive (+) → Terminal 1 Battery negative (-) → Terminal 4 | Unlock |
![]() |
RHD:
Apply the battery voltage to the door lock motor and check the operation of the door lock motor.
| Measurement Condition | Specified Condition |
| Battery positive (+) → Terminal 4 Battery negative (-) → Terminal 3 | Lock |
| Battery positive (+) → Terminal 3 Battery negative (-) → Terminal 4 | Unlock |
|
| ||||
| OK | |
| 2.CHECK HARNESS AND CONNECTOR (MAIN BODY ECU - REAR DOOR LOCK ASSEMBLY RH) |
![]() |
LHD:
Disconnect the 4A main body ECU connector.
Disconnect the H3 door lock connector.
Measure the resistance of the wire harness side connectors.
| Tester Connection | Specified Condition |
| 4A-3 (ACT+) - H3-4 | Below 1 Ω |
| 4A-4 (ACT-) - H3-1 | Below 1 Ω |
| 4A-3 (ACT+) or H3-4 - Body ground | 10 kΩ or higher |
| 4A-4 (ACT-) or H3-1 - Body ground | 10 kΩ or higher |
Reconnect the main body ECU connector.
Reconnect the door lock connector.
RHD:
Disconnect the 4A main body ECU connector.
Disconnect the H3 door lock connector.
Measure the resistance of the wire harness side connectors.
| Tester Connection | Specified Condition |
| 4A-3 (ACT+) - H3-4 | Below 1 Ω |
| 4A-4 (ACT-) - H3-3 | Below 1 Ω |
| 4A-3 (ACT+) or H3-4 - Body ground | 10 kΩ or higher |
| 4A-4 (ACT-) or H3-3 - Body ground | 10 kΩ or higher |
Reconnect the main body ECU connector.
Reconnect the door lock connector.
|
| ||||
| OK | ||
| ||