Home › TRANSMISSION · U340E AUTOMATIC TRANSAXLE › AUTOMATIC TRANSAXLE SYSTEM

DTC    P0710    Transmission Fluid Temperature Sensor "A" Circuit

DTC    P0712    Transmission Fluid Temperature Sensor "A" Circuit Low Input

DTC    P0713    Transmission Fluid Temperature Sensor "A" Circuit High Input

for Preparation Click here


DESCRIPTION

G031389E08
The ATF (Automatic Transmission Fluid) temperature sensor converts the fluid temperature into a resistance value which is input to the ECM.
The sensor resistance changes with the transmission fluid temperature. As the temperature rises, the sensor resistance decreases. The ECM applies a voltage to the temperature sensor through ECM terminal THO1, and the ECM calculates the fluid temperature based on the voltage signal.

HINT:
The ATF temperature is likely to increase under conditions such as towing, climbing hills and in heavy traffic.


DTC No.
DTC Detection Condition
Trouble Area
P0710
Both (a) and (b) are detected momentarily within 0.5 seconds when neither P0712 nor P0713 is detected. (1-trip detection logic)
(a) ATF temperature sensor resistance is less than 79 Ω.
(b) ATF temperature sensor resistance is more than 156 kΩ.

HINT:
Within 0.5 seconds, malfunction switches from (a) to (b) or from (b) to (a).

  1. Open or short in ATF temperature sensor circuit
  2. Transmission wire (ATF temperature sensor)
  3. ECM
P0712
ATF temperature sensor resistance is less than 79 Ω for 0.5 seconds or more. (1-trip detection logic)
  1. Short in ATF temperature sensor circuit
  2. Transmission wire (ATF temperature sensor)
  3. ECM
P0713
Following condition continues for 0.5 seconds or more. (1-trip detection logic)
ATF temperature sensor resistance is more than 156 kΩ after 15 minutes or more after starting engine.
  1. Open in ATF temperature sensor circuit
  2. Transmission wire (ATF temperature sensor)
  3. ECM

MONITOR DESCRIPTION

The ATF temperature sensor converts the ATF temperature to an electrical resistance value. Based on the resistance, the ECM determines the ATF temperature and detects opens or shorts in the ATF temperature circuit. If the resistance value of the ATF temperature is less than 79 Ω*1 or more than 156 kΩ*2, the ECM interprets this as a fault in the ATF sensor or wiring. The ECM turns on the MIL and stores the DTC.
*1: 150°C (302°F) or more is indicated regardless of the actual ATF temperature.
*2: -40°C (-40°F) is indicated regardless of the actual ATF temperature.

HINT:
The ATF temperature can be checked on the intelligent tester display.


WIRING DIAGRAM


C117649E01


INSPECTION PROCEDURE


DATA LIST

HINT:
Using the Data List displayed by the intelligent tester, you can read the values of the switches, sensors, actuators and so on without parts removal. Reading the Data List as the first step of troubleshooting is one method of shortening labor time.

NOTICE:
In the table below, the values listed under "Normal Condition" are reference values. Do not depend solely on these reference values when deciding whether a part is faulty or not.

  1. Warm up the engine.

  2. Turn the ignition switch off.

  3. Connect the intelligent tester to the DLC3.

  4. Turn the ignition switch to ON.

  5. Turn on the tester.

  6. Select the following items: Powertrain / Engine and ECT / Data List.

  7. In accordance with the display on the tester, read the Data List.

    Item
    Measurement Item/
    Range (display)
    Normal Condition
    Diagnostic Note
    A/T Oil Temperature 1
    ATF Temperature Sensor Value/
    min.: -40°C (-40°F)
    max.: 215°C (419°F)
    1. After Stall Test; Approximately 80°C (176°F)
    2. Equal to ambient temperature when cold soak
    If value is -40°C (-40°F) or 150°C (302°F) or more, ATF temperature sensor circuit is open or short.

    HINT:
    When DTC P0712 is output and the intelligent tester reading is 150°C (302°F) or more, there is a short circuit.
    When DTC P0713 is output and the intelligent tester reading is -40°C (-40°F), there is an open circuit.
    Measure the resistance between terminal THO1 and the body ground.

    Temperature Displayed
    Malfunction
    -40°C (-40°F)
    Open circuit
    150°C (302°F) or more
    Short circuit

    HINT:
    If a circuit related to the ATF (Automatic Transmission Fluid) temperature sensor becomes open, P0713 is immediately set (within 0.5 seconds).
    When P0713 is set, P0711 cannot be detected.

1.INSPECT TRANSMISSION WIRE (ATF TEMPERATURE SENSOR)
C117650E01
  1. Disconnect the transmission wire connector from the transaxle.

  1. Measure the resistance.

    Standard resistance:
    Tester Connection
    Specified Condition
    1 (THO) - 6 (E2)
    79 Ω to 156 kΩ
    1 (THO) - Body ground
    10 kΩ or higher
    6 (E2) - Body ground
    10 kΩ or higher

    HINT:
    If the resistance is outside the specified range at either of the ATF temperature shown in the table below, the driveability of the vehicle may be affected.

    Standard resistance:
    ATF Temperature
    Specified Condition
    20°C (68°F)
    3 to 4 kΩ
    110°C (230°F)
    0.22 to 0.28 kΩ



NG
REPAIR OR REPLACE TRANSMISSION WIRE
OK


2.CHECK HARNESS AND CONNECTOR (TRANSMISSION WIRE - ECM)
A107892E03
  1. Connect the transmission wire connector to the transaxle.

  1. Disconnect the ECM connector.

  1. Measure the resistance.

    Standard resistance:
    Tester Connection
    Specified Condition
    72 (THO1) - 95 (ETHO)
    79 Ω to 156 kΩ
    72 (THO1) - Body ground
    10 kΩ or higher
    95 (ETHO) - Body ground
    10 kΩ or higher



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK

REPLACE ECM