DTC P0973 Shift Solenoid "A" Control Circuit Low (Shift Solenoid Valve S1) |
DTC P0974 Shift Solenoid "A" Control Circuit High (Shift Solenoid Valve S1) |
| DTC No. | DTC Detection Condition | Trouble Area |
| P0973 | ECM detects short in solenoid valve S1 circuit 4 times when solenoid valve S1 is operated. (1-trip detection logic) |
|
| P0974 | ECM detects open in solenoid valve S1 circuit 4 times when solenoid valve S1 is not operated. (1-trip detection logic) |
|

| Gearshift controlled by ECM | 1st | 2nd | 3rd | 4th |
| Shift solenoid valve S1 | ON | ON | OFF | OFF |
| 1.INSPECT TRANSMISSION WIRE (SHIFT SOLENOID VALVE S1) |
![]() |
Disconnect the transmission wire connector from the transaxle.
Measure the resistance.
| Tester Connection | Specified Condition |
| 5 (S1) - Body ground | 11 Ω to 15 Ω at 20°C (68°F) |
|
| ||||
| OK | |
| 2.CHECK HARNESS AND CONNECTOR (TRANSMISSION WIRE - ECM) |
![]() |
Connect the transmission connector to the transaxle.
Disconnect the ECM connector.
Measure the resistance.
| Tester Connection | Specified Condition |
| 79 (S1) - Body ground | 11 Ω to 15 Ω at 20°C (68°F) |
|
| ||||
| OK | ||
| ||
| 3.INSPECT SHIFT SOLENOID VALVE S1 |
![]() |
Remove shift solenoid valve S1.
Measure the resistance.
| Tester Connection | Specified Condition |
| Solenoid Connector (S1) - Solenoid Body (S1) | 11 to 15 Ω at 20°C (68°F) |
Connect the positive (+) lead to the terminal of the solenoid connector and the negative (-) lead to the solenoid body to check the solenoid valve operation.
|
| ||||
| OK | ||
| ||