Home › TRANSMISSION · U340E AUTOMATIC TRANSAXLE › AUTOMATIC TRANSAXLE SYSTEM

DTC    P0973    Shift Solenoid "A" Control Circuit Low (Shift Solenoid Valve S1)

DTC    P0974    Shift Solenoid "A" Control Circuit High (Shift Solenoid Valve S1)

for Preparation Click here


DESCRIPTION

Shifting from 1st to 4th is performed in combination with the ON and OFF operations of shift solenoid valves S1 and S2 which are controlled by the ECM. If an open or short circuit occurs in either of the shift solenoid valves, the ECM controls the remaining normal shift solenoid valve to allow the vehicle to be driven smoothly.
(If an open or short circuit occurs, the ECM stops sending currents to the affected circuit.)
Fail-safe function (Click here).

DTC No.
DTC Detection Condition
Trouble Area
P0973
ECM detects short in solenoid valve S1 circuit 4 times when solenoid valve S1 is operated. (1-trip detection logic)
  1. Short in shift solenoid valve S1 circuit
  2. Shift solenoid valve S1
  3. ECM
P0974
ECM detects open in solenoid valve S1 circuit 4 times when solenoid valve S1 is not operated. (1-trip detection logic)
  1. Open in shift solenoid valve S1 circuit
  2. Shift solenoid valve S1
  3. ECM

MONITOR DESCRIPTION

The ECM commands gearshift by turning the shift solenoid valves ON/OFF. When there is an open or short circuit in the shift solenoid valve S1 circuit, the ECM detects the problem and the MIL comes on. Illuminating the MIL, the ECM performs the fail-safe and turns the other functioning shift solenoid valve ON/OFF.
(If an open or short circuit occurs, the ECM stops sending currents to the affected circuit.)

WIRING DIAGRAM


C117933E02


INSPECTION PROCEDURE


HINT:
Shift solenoid valve S1 is turned on/off normally when the shift lever is in the D position:

Gearshift controlled by ECM
1st
2nd
3rd
4th
Shift solenoid valve S1
ON
ON
OFF
OFF

1.INSPECT TRANSMISSION WIRE (SHIFT SOLENOID VALVE S1)
C117650E03
  1. Disconnect the transmission wire connector from the transaxle.

  1. Measure the resistance.

    Standard resistance:
    Tester Connection
    Specified Condition
    5 (S1) - Body ground
    11 Ω to 15 Ω at 20°C (68°F)



NG
Go to step 3
OK


2.CHECK HARNESS AND CONNECTOR (TRANSMISSION WIRE - ECM)
C130155E03
  1. Connect the transmission connector to the transaxle.

  1. Disconnect the ECM connector.

  1. Measure the resistance.

    Standard resistance:
    Tester Connection
    Specified Condition
    79 (S1) - Body ground
    11 Ω to 15 Ω at 20°C (68°F)



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK

REPLACE ECM 

3.INSPECT SHIFT SOLENOID VALVE S1
C130146E01
  1. Remove shift solenoid valve S1.

  1. Measure the resistance.

    Standard resistance:
    Tester Connection
    Specified Condition
    Solenoid Connector (S1) - Solenoid Body (S1)
    11 to 15 Ω at 20°C (68°F)

  1. Connect the positive (+) lead to the terminal of the solenoid connector and the negative (-) lead to the solenoid body to check the solenoid valve operation.

OK:
The solenoid makes operating sounds.



NG
REPLACE SHIFT SOLENOID VALVE S1
OK

REPAIR OR REPLACE TRANSMISSION WIRE