Home › BRAKE › BRAKE CONTROL › ANTI-LOCK BRAKE SYSTEM (for Sedan)

ANTI-LOCK BRAKE SYSTEM (for Sedan) > CHECK FOR INTERMITTENT PROBLEMS

for Preparation Click here



CHECK FOR INTERMITTENT PROBLEMS

HINT:
A momentary interruption (open circuit) in the connectors and/or wire harness between the sensors and ECUs can be detected using the ECU Data List function of the intelligent tester.

  1. Turn the ignition switch off and connect the intelligent tester to the DLC3.

  2. Turn the ignition switch to ON. Follow the directions on the intelligent tester to display the Data List and select areas where momentary interruption should be monitored.

    HINT:
    1. A momentary interruption (open circuit) cannot be detected for 3 seconds after the ignition switch is turned to ON (initial check).
    2. If the status remains on (error displayed), check the continuity between the ECU and the sensors, or between ECUs.
    3. The "Error" display on the intelligent tester remains on for 1 second after the harness signal changes from momentary interruption (open circuit) to normal condition.


    ABS/VSC/TRC 
    Tester Display
    Measurement Item/Range
    Normal Condition
    Diagnostic Note
    FR Speed Open
    FR speed sensor open detection / Error or Normal
    Error: Momentary interruption
    Normal: Normal
    -
    FL Speed Open
    FL speed sensor open detection / Error or Normal
    Error: Momentary interruption
    Normal: Normal
    -
    RR Speed Open
    RR speed sensor open detection / Error or Normal
    Error: Momentary interruption
    Normal: Normal
    -
    RL Speed Open
    RL speed sensor open detection / Error or Normal
    Error: Momentary interruption
    Normal: Normal
    -

  3. While observing the screen, gently jiggle the connector or wire harness between the ECU and sensors, or between ECUs.

    OK:
    Error display does not change.

    HINT:
    If the display changes, the connector and/or the wire harness has caused a momentary interruption of the circuit. Repair or replace the connector and/or wire harness because one of them is faulty.


SYMPTOM SIMULATION