Home › BODY › WINDSHIELD / WINDOWGLASS › POWER WINDOW CONTROL SYSTEM

POWER WINDOW CONTROL SYSTEM > Power Windows do not Operate at All

for Preparation Click here


DESCRIPTION

If all of the power windows do not operate, the power window regulator master switch may have no power or may be malfunctioning.

WIRING DIAGRAM


B119964E02


INSPECTION PROCEDURE

1.INSPECT FUSES (ECU-B, ECU-IG)


    B128295E01
  1. Remove the ECU-B fuse from the engine room relay block.

  1. Remove the ECU-IG fuse from the main body ECU.

  1. Measure the resistance.

    Standard resistance:
    Below 1Ω

  1. Reinstall the fuses.



NG
REPLACE FUSE
OK


2.INSPECT MAIN BODY ECU (PWR RELAY)


    B119965E01
  1. Remove the POWER fuse from the main body ECU.

  1. Turn the ignition switch to ON.

  1. Turn the ignition switch ON.

  1. Measure the voltage between the POWER fuse terminal of the main body ECU and body ground.

    Standard voltage:
    Tester Connections
    Ignition Switch Conditions
    Specified Conditions
    POWER fuse terminal (1) - Body ground
    ON
    10 to 14 V

  1. Reinstall the POWER fuse.



NG
REPLACE MAIN BODY ECU (PWR RELAY)
OK


3.CHECK HARNESS AND CONNECTOR (POWER WINDOW MASTER SWITCH - BATTERY AND BODY GROUND)


    B129851E01
  1. Disconnect the G1 or F7 power window regulator master switch connector.

  1. Measure the voltage of the wire harness side connector.

    Standard voltage:
    w/o rear power window
    LHD 
    Tester Connection
    Condition
    Specified Condition
    G1-15 (B)- Body ground
    Ignition switch ON
    10 to 14 V
    RHD 
    Tester Connection
    Condition
    Specified Condition
    F7-15 (B)- Body ground
    Ignition switch ON
    10 to 14 V


    Standard voltage:
    w/ rear power window
    LHD 
    Tester Connection
    Condition
    Specified Condition
    G1-6 (B)- Body ground
    Ignition switch ON
    10 to 14 V
    RHD 
    Tester Connection
    Condition
    Specified Condition
    F7-6 (B)- Body ground
    Ignition switch ON
    10 to 14 V

  1. Measure the resistance of the wire harness side connector.

    Standard resistance:
    w/o rear power window
    LHD 
    Tester Connection
    Specified Condition
    G1-7 (E)- Body ground
    Below 1 Ω
    RHD 
    Tester Connection
    Specified Condition
    F7-7 (E)- Body ground
    Below 1 Ω


    Standard resistance:
    w/ rear power window
    LHD 
    Tester Connection
    Specified Condition
    G1-1 (E)- Body ground
    Below 1 Ω
    RHD 
    Tester Connection
    Specified Condition
    F7-9 (E)- Body ground
    Below 1 Ω

  1. Reconnect the power window regulator master switch assembly connector.



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK

REPLACE POWER WINDOW REGULATOR MASTER SWITCH ASSEMBLY