Home › ENGINE ยท 2NZ-FE › EMISSION CONTROL › HEATED OXYGEN SENSOR (for Sensor 1)

HEATED OXYGEN SENSOR (for Sensor 1) > INSTALLATION

for Preparation Click here



1. INSTALL HEATED OXYGEN SENSOR


A115426
  1. Using SST, install the heated oxygen sensor.

    SST
    09224-00010  

    Torque:
    44 N*m{ 449 kgf*cm , 32 ft.*lbf }

  1. Connect the heated oxygen sensor connector and clamp.



2. CONNECT CABLE TO NEGATIVE BATTERY TERMINAL

Torque:
5.4 N*m{ 55 kgf*cm , 48 in.*lbf }



3. CHECK FOR EXHAUST GAS LEAKAGE