Home › ENGINE · 1NZ-FE › EMISSION CONTROL › HEATED OXYGEN SENSOR (for Sensor 2)

HEATED OXYGEN SENSOR (for Sensor 2) > INSPECTION

for Preparation Click here



1. INSPECT HEATED OXYGEN SENSOR


A094812E01
  1. Check the resistance.

    1. Using an ohmmeter, measure the resistance between the terminals.

      Standard resistance:
      Tester Connection
      Specified Condition
      1 (HT1B) - 2 (+B)
      11 to 16 Ω at 20 °C (68 °F)
      1 (HT1B) - 4 (E2)
      10 kΩ or higher

      If the resistance is not as specified, replace the sensor.