INTEGRATION RELAY > INSPECTION |
| 1. INSPECT INTEGRATION NO.1 RELAY |
![]() |
Inspect EFI (20A) fuse.
Disconnect the fuse.
Using an ohmmeter, measure the resistance of the fuse.
| Tester Connection | Specified condition |
| 1 - 2 | Below 1 Ω |
Inspect EFI relay.
Using an ohmmeter, measure the resistance between the terminals.
| Tester Connection | Specified condition |
| A1 - C1 | Below 1 Ω |
| A1 - A4 | 10 kΩ or higher |
| A4 - C1 | 10 kΩor higher |
| A1 - A4 | Below 1 Ω (Apply battery voltage between terminals A2 and A3) |
| A4 - C1 | Below 1 Ω (Apply battery voltage between terminals A2 and A3) |