Home › BODY ELECTRICAL › LIGHTING › ROOM LIGHT ASSEMBLY

ROOM LIGHT ASSEMBLY > INSPECTION

for Preparation Click here



1. INSPECT ROOM LIGHT ASSEMBLY


E114448E01
  1. Check the resistance.

    1. Using an ohmmeter, measure the resistance and check the results in accordance with the value(s) in the table below.

      Standard Resistance:
      Tester Connection
      Condition
      Specified Condition
      -
      OFF
      10 kΩ or higher
      CTY - B
      DOOR
      Below 1 Ω
      B - E
      ON
      Below 1 Ω

      If the result is not as specified, replace the room light.

  1. Check the light operation.

    1. Connect the positive (+) battery lead to terminal B and the negative (-) battery lead to terminal CTY, then check that the light illuminates when the switch is in the DOOR position.

      Standard:
      Light illuminates.

      If the light does not illuminate, replace the bulb.

    2. Connect the positive (+) battery lead to terminal B and the negative (-) battery lead to terminal E, then check that the light illuminates when the switch is in the ON position.

      Standard:
      Light illuminates.

      If the light does not illuminate, replace the bulb.