POWER WINDOW MASTER SWITCH (for Sedan) > INSPECTION |
| 1. INSPECT POWER WINDOW REGULATOR MASTER SWITCH ASSEMBLY |
![]() |
for LHD:
Check the resistance.
Using an ohmmeter, measure the resistance and check the results in accordance with the value(s) in the tables below.
| Window Lock Switch Condition | Power Window Switch Condition | Tester Connection | Specified Condition |
| Always (ON / OFF) | UP | 3 (U) - 6 (B) 1 (E) - 4 (D) | Below 1 Ω |
| Always (ON / OFF) | OFF | 1 (E) - 3 (U) 1 (E) - 4 (D) | Below 1 Ω |
| Always (ON / OFF) | DOWN MANUAL | 4 (D) - 6 (B) 1 (E) - 3 (U) | Below 1 Ω |
| Always (ON / OFF) | DOWN AUTO | 1 (E) - 3 (U) 4 (D) - 6 (B) | Below 1 Ω |
| Window Lock Switch Condition | Power Window Switch Condition | Tester Connection | Specified Condition |
| OFF | UP | 6 (B) - 16 (U) 1 (E) - 15 (D) | Below 1 Ω |
| OFF | OFF | 1 (E) - 16 (U) 1 (E) - 15 (D) | Below 1 Ω |
| OFF | DOWN | 6 (B) - 15 (D) 1 (E) - 16 (U) | Below 1 Ω |
| ON | UP | 6 (B) - 16 (U) | Below 1 Ω |
| ON | UP | 1 (E) - 15 (D) | 10 kΩ or higher |
| ON | OFF | 15 (D) - 16 (U) | Below 1 Ω |
| ON | DOWN | 6 (B) - 15 (D) | Below 1 Ω |
| ON | DOWN | 1 (E) - 16 (U) | 10 kΩ or higher |
| Window Lock Switch Condition | Power Window Switch Condition | Tester Connection | Specified Condition |
| OFF | UP | 6 (B) - 12 (U) 1 (E) - 13 (D) | Below 1 Ω |
| OFF | OFF | 1 (E) - 12 (U) 1 (E) - 13 (D) | Below 1 Ω |
| OFF | DOWN | 6 (B) - 13 (D) 1 (E) - 12 (U) | Below 1 Ω |
| ON | UP | 6 (B) - 12 (U) | Below 1 Ω |
| ON | UP | 1 (E) - 13 (D) | 10 kΩ or higher |
| ON | OFF | 12 (U) - 13 (D) | Below 1 Ω |
| ON | DOWN | 6 (B) - 13 (D) | Below 1 Ω |
| ON | DOWN | 1 (E) - 12 (U) | 10 kΩ or higher |
| Window Lock Switch Condition | Power Window Switch Condition | Tester Connection | Specified Condition |
| OFF | UP | 6 (B) - 10 (U) 1 (E) - 18 (D) | Below 1 Ω |
| OFF | OFF | 1 (E) - 10 (U) 1 (E) - 18 (D) | Below 1 Ω |
| OFF | DOWN | 6 (B) - 18 (D) 1 (E) - 10 (U) | Below 1 Ω |
| ON | UP | 6 (B) - 10 (U) | Below 1 Ω |
| ON | UP | 1 (E) - 18 (D) | 10 kΩ or higher |
| ON | OFF | 10 (U) - 18 (D) | Below 1 Ω |
| ON | DOWN | 6 (B) - 18 (D) | Below 1 Ω |
| ON | DOWN | 1 (E) - 10 (U) | 10 kΩ or higher |
for LHD:
Check the illumination operation.
Apply battery voltage to the power window regulator master switch and check that the illumination comes on.
| Measurement Condition | Specified Condition |
| Battery positive (+) → Terminal 6 (B) Battery negative (-) → Terminal 1 (E) | Illumination comes on |
![]() |
for RHD:
Check the resistance.
Using an ohmmeter, measure the resistance and check the results in accordance with the value(s) in the tables below.
| Window Lock Switch Condition | Power Window Switch Condition | Tester Connection | Specified Condition |
| Always (ON / OFF) | UP | 4 (U) - 6 (B) 9 (E) - 3 (D) | Below 1 Ω |
| Always (ON / OFF) | OFF | 9 (E) - 4 (U) 9 (E) - 3 (D) | Below 1 Ω |
| Always (ON / OFF) | DOWN MANUAL | 3 (D) - 6 (B) 9 (E) - 4 (U) | Below 1 Ω |
| Always (ON / OFF) | DOWN AUTO | 9 (E) - 4 (U) 3 (D) - 6 (B) | Below 1 Ω |
| Window Lock Switch Condition | Power Window Switch Condition | Tester Connection | Specified Condition |
| OFF | UP | 6 (B) - 12(U) 9 (E) - 13 (D) | Below 1 Ω |
| OFF | OFF | 9 (E) - 12(U) 9 (E) - 13 (D) | Below 1 Ω |
| OFF | DOWN | 6 (B) - 13 (D) 9 (E) - 12(U) | Below 1 Ω |
| ON | UP | 6 (B) - 12(U) | Below 1 Ω |
| ON | UP | 9 (E) - 13 (D) | 10 kΩ or higher |
| ON | OFF | 13 (D) - 12(U) | Below 1 Ω |
| ON | DOWN | 6 (B) - 13 (D) | Below 1 Ω |
| ON | DOWN | 9 (E) - 12 (U) | 10 kΩ or higher |
| Window Lock Switch Condition | Power Window Switch Condition | Tester Connection | Specified Condition |
| OFF | UP | 6 (B) - 18 (U) 9 (E) - 10 D) | Below 1 Ω |
| OFF | OFF | 9 (E) - 18 (U) 9 (E) - 10 (D) | Below 1 Ω |
| OFF | DOWN | 6 (B) - 10 (D) 9 (E) - 18 (U) | Below 1 Ω |
| ON | UP | 6 (B) - 18 (U) | Below 1 Ω |
| ON | UP | 9 (E) - 10 (D) | 10 kΩ or higher |
| ON | OFF | 18 (U) - 10 (D) | Below 1 Ω |
| ON | DOWN | 6 (B) - 10 (D) | Below 1 Ω |
| ON | DOWN | 9 (E) - 18 (U) | 10 kΩ or higher |
| Window Lock Switch Condition | Power Window Switch Condition | Tester Connection | Specified Condition |
| OFF | UP | 6 (B) - 16 (U) 9 (E) - 15 (D) | Below 1 Ω |
| OFF | OFF | 9 (E) - 16 (U) 9 (E) - 15 (D) | Below 1 Ω |
| OFF | DOWN | 6 (B) - 15 (D) 9 (E) - 16 (U) | Below 1 Ω |
| ON | UP | 6 (B) - 16 (U) | Below 1 Ω |
| ON | UP | 9 (E) - 15 (D) | 10 kΩ or higher |
| ON | OFF | 16 (U) - 15 (D) | Below 1 Ω |
| ON | DOWN | 6 (B) - 15 (D) | Below 1 Ω |
| ON | DOWN | 9 (E) - 16 (U) | 10 kΩ or higher |
for RHD:
Check the illumination operation.
Apply battery voltage to the power window regulator master switch and check that the illumination comes on.
| Measurement Condition | Specified Condition |
| Battery positive (+) → Terminal 6 (B) Battery negative (-) → Terminal 9 (E) | Illumination comes on |