DTC    B1413/13    Evaporator Temperature Sensor Circuit

for Preparation Click here


DESCRIPTION

The No. 1 cooler thermistor (evaporator temperature sensor) is installed on the evaporator in the air conditioner unit to detect the temperature of the cooled air that has passed through the evaporator and to control the air conditioner. It sends signals to the air conditioning amplifier, which change in accordance with the resistance of the No. 1 cooler thermistor (evaporator temperature sensor). As the temperature decreases, the resistance increases. As the temperature increases, the resistance decreases. The air conditioning amplifier applies a voltage (5V) to the No. 1 cooler thermistor (evaporator temperature sensor) and reads voltage changes as changes in the resistance of the No. 1 cooler thermistor (evaporator temperature sensor). This sensor is used for frost prevention.

DTC No.
DTC Detection Condition
Trouble Area
B1413/13
Open or short in evaporator temperature sensor circuit
  1. No. 1 cooler thermistor (evaporator temperature sensor)
  2. Harness and connector between No. 1 cooler thermistor (evaporator temperature sensor) and air conditioning amplifier
  3. Air conditioning amplifier

WIRING DIAGRAM


E114518E04


INSPECTION PROCEDURE

1.READ VALUE USING INTELLIGENT TESTER (EVAP FIN TEMP)
  1. Connect the intelligent tester to the DLC3.

  1. Turn the ignition switch on (IG) and turn the intelligent tester main switch ON.

  1. Select the item below in the Data List, and read the value displayed on the intelligent tester.

    Data List / Air Conditioner:

    Item
    Measurement Item / Display (Range)
    Normal Condition
    Diagnostic Note
    Evap Fin Temp
    Evaporator temperature sensor / Min.: -29.7°C (-21.46°F)
    Max.: 59.55°C (139.019°F)
    Actual evaporator temperature is displayed
    Open circuit: -29.7°C (-21.46°F)
    Short circuit: 59.55°C (139.019°F)

    OK:
    The display is as specified in the normal condition column.


    Result:

    Result
    Proceed to
    NG
    A
    OK (Checking from the PROBLEM SYMPTOMS TABLE)
    B
    OK (Checking from the DTC)
    C



B
PROCEED TO NEXT CIRCUIT INSPECTION SHOWN IN PROBLEM SYMPTOMS TABLE

C
REPLACE AIR CONDITIONING AMPLIFIER
A


2.INSPECT NO. 1 COOLER THERMISTOR (EVAPORATOR TEMPERATURE SENSOR)
E115010E22
  1. Remove the No. 1 cooler thermistor (evaporator temperature sensor).

  1. Measure the resistance.

    Standard resistance:
    Tester Connection
    Condition
    Specified Condition
    E2-1 - E2-2
    -10°C (14°F)
    7.30 to 9.10 kΩ
    E2-1 - E2-2
    -5°C (23°F)
    5.65 to 6.95 kΩ
    E2-1 - E2-2
    0°C (32°F)
    4.40 to 5.35 kΩ
    E2-1 - E2-2
    5°C (41°F)
    3.40 to 4.15 kΩ
    E2-1 - E2-2
    10°C (50°F)
    2.70 to 3.25 kΩ
    E2-1 - E2-2
    15°C (59°F)
    2.14 to 2.58 kΩ
    E2-1 - E2-2
    20°C (68°F)
    1.71 to 2.05 kΩ
    E2-1 - E2-2
    25°C (77°F)
    1.38 to 1.64 kΩ
    E2-1 - E2-2
    30°C (86°F)
    1.11 to 1.32 kΩ

    NOTICE:
    1. Touching the sensor even slightly may change the resistance value. Be sure to hold the connector of the sensor.
    2. When measuring, the sensor temperature must be the same as the ambient temperature.

    HINT:
    As the temperature increases, the resistance decreases (see the graph).

  1. Reinstall the No. 1 cooler thermistor (evaporator temperature sensor).



NG
REPLACE NO. 1 COOLER THERMISTOR (EVAPORATOR TEMPERATURE SENSOR)
OK


3.CHECK HARNESS AND CONNECTOR (No. 1 COOLER THERMISTOR - AIR CONDITIONING AMPLIFIER)
E142748E01
  1. Disconnect the E2 No. 1 cooler thermistor (evaporator temperature sensor) connector.

  1. Disconnect the E8 air conditioning amplifier connector.

  1. Measure the resistance.

    Standard resistance:
    Tester Connection
    Specified Condition
    E2-2 - E8-10 (TE)
    Below 1 Ω
    E2-1 - E8-4 (SG-2)
    Below 1 Ω
    E2-2 - Body ground
    1 MΩ or higher
    E2-1 - Body ground
    1 MΩ or higher

  1. Reconnect the No. 1 cooler thermistor (evaporator temperature sensor) connector.

  1. Reconnect the air conditioning amplifier connector.



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK

REPLACE AIR CONDITIONING AMPLIFIER