Home › TRANSMISSION · U441E AUTOMATIC TRANSAXLE › AUTOMATIC TRANSAXLE SYSTEM

DTC    P2769    Short in Torque Converter Clutch Solenoid Circuit (Shift Solenoid Valve SL)

DTC    P2770    Open in Torque Converter Clutch Solenoid Circuit (Shift Solenoid Valve SL)

for Preparation Click here


DESCRIPTION

Shift solenoid valve SL is turned ON and OFF by signals from the ECM to control the hydraulic pressure in the lock-up relay valve, which then controls the operation of the lock-up clutch.
Fail-safe function:
  1. If the ECM detects a malfunction, it turns shift solenoid valve SL OFF.
  1. The system cannot control the lock-up relay valve. (No relation to 3-4 shift control)

DTC No.
DTC Detection Condition
Trouble Area
P2769
ECM detects short in solenoid valve SL circuit when solenoid valve SL operated. (Solenoid resistance: 8 Ω or less)
(Except leaded gasoline sedan model: 2-trip detection logic)
(Leaded gasoline sedan model:1-trip detection logic)
  1. Short in shift solenoid valve SL circuit
  2. Shift solenoid valve SL
  3. ECM
P2770
ECM detects open in solenoid valve SL circuit when solenoid valve SL not operated. (Solenoid resistance: 100 kΩ or more)
(Except leaded gasoline sedan model: 2-trip detection logic)
(Leaded gasoline sedan model:1-trip detection logic)
  1. Open in shift solenoid valve SL circuit
  2. Shift solenoid valve SL
  3. ECM

MONITOR DESCRIPTION

Based on the signals from the throttle position sensor, the mass airflow meter and the crankshaft position sensor, the ECM sends a signal to shift solenoid valve SL to regulate the hydraulic pressure and provide smoother gearshifting. Shift solenoid valve SL responds to the signals from the ECM. The valve controls the lock-up relay valve to perform the torque converter lock-up function. If the ECM detects an open or short circuit of shift solenoid valve SL, it illuminates the MIL and sets a DTC.

WIRING DIAGRAM


C117933E04


INSPECTION PROCEDURE

1.INSPECT TRANSMISSION WIRE (SHIFT SOLENOID VALVE SL)


    C117650E07
  1. Disconnect the transmission wire connector from the transaxle.

  1. Measure the resistance.

    Standard resistance:
    Tester Connection
    Specified Condition
    4 (SL) - Body ground
    11 to 15 Ω at 20°C (68°F)



NG
Go to step 3
OK


2.CHECK HARNESS AND CONNECTOR (TRANSMISSION WIRE - ECM)


    C130155E05
  1. Connect the transmission connector to the transaxle.

  1. Disconnect the ECM connector.

  1. Measure the resistance.

    Standard resistance:
    Tester Connection
    Specified Condition
    57 (SL) - Body ground
    11 to 15 Ω at 20°C (68°F)



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK

REPLACE ECM 

3.INSPECT SHIFT SOLENOID VALVE SL


    C117940E01
  1. Remove shift solenoid valve SL.

  1. Measure the resistance.

    Standard resistance:
    Tester Connection
    Specified Condition
    Solenoid Connector (SL) - Solenoid Body (SL)
    11 to 15 Ω at 20°C (68°F)

  1. Connect the positive (+) lead to the terminal of the solenoid connector and the negative (-) lead to the solenoid body to check the solenoid valve operation.

OK:
The solenoid makes operating sounds.



NG
REPLACE SHIFT SOLENOID VALVE SL
OK

REPAIR OR REPLACE TRANSMISSION WIRE