DTC P2769 Short in Torque Converter Clutch Solenoid Circuit (Shift Solenoid Valve SL) |
DTC P2770 Open in Torque Converter Clutch Solenoid Circuit (Shift Solenoid Valve SL) |
| DTC No. | DTC Detection Condition | Trouble Area |
| P2769 | ECM detects short in solenoid valve SL circuit when solenoid valve SL operated. (Solenoid resistance: 8 Ω or less) (2-trip detection logic) |
|
| P2770 | ECM detects open in solenoid valve SL circuit when solenoid valve SL not operated. (Solenoid resistance: 100 kΩ or more) (2-trip detection logic) |
|

| 1.INSPECT TRANSMISSION WIRE (SHIFT SOLENOID VALVE SL) |
![]() |
Disconnect the transmission wire connector from the transaxle.
Measure the resistance.
| Tester Connection | Specified Condition |
| 4 (SL) - Body ground | 11 to 15 Ω at 20°C (68°F) |
|
| ||||
| OK | |
| 2.CHECK HARNESS AND CONNECTOR (TRANSMISSION WIRE - ECM) |
![]() |
Connect the transmission connector to the transaxle.
Disconnect the ECM connector.
Measure the resistance.
| Tester Connection | Specified Condition |
| 57 (SL) - Body ground | 11 to 15 Ω at 20°C (68°F) |
|
| ||||
| OK | ||
| ||
| 3.INSPECT SHIFT SOLENOID VALVE SL |
![]() |
Remove shift solenoid valve SL.
Measure the resistance.
| Tester Connection | Specified Condition |
| Solenoid Connector (SL) - Solenoid Body (SL) | 11 to 15 Ω at 20°C (68°F) |
Connect the positive (+) lead to the terminal of the solenoid connector and the negative (-) lead to the solenoid body to check the solenoid valve operation.
|
| ||||
| OK | ||
| ||