Home › HEATER & AIR CONDITIONING SYSTEM › AIR CONDITIONING › AIR CONDITIONING SYSTEM

DTC    B1451/51    Compressor Solenoid Circuit

for Preparation Click here


DESCRIPTION

In this circuit, the compressor receives a refrigerant compression demand signal from the air conditioning amplifier.
Based on this signal, the compressor changes the degree of refrigerant compression.

DTC No.
DTC Detection Condition
Trouble Area
B1451/51
Open or short in solenoid of externally changeable compressor circuit
  1. Compressor and pulley
  2. Harness and connector between air conditioning amplifier and compressor and pulley
  3. Air conditioning amplifier

WIRING DIAGRAM


E115016E03


INSPECTION PROCEDURE

1.READ VALUE USING INTELLIGENT TESTER (REG CTRL CURRNT)
  1. Connect the intelligent tester to the DLC3.

  1. Turn the ignition switch on (IG) and turn the intelligent tester main switch ON.

  1. Select the items below in the Data List, and read the value displayed on the intelligent tester.

    Data List / Air Conditioner:

    ITEM
    Measurement Item / Display (Range)
    Normal Condition
    Diagnostic Note
    Reg Ctrl Currnt
    Regulator control current /
    Min.: 0 A
    MAX.: 0.997 A
    Value changes between 0 A and 0.997 A in accordance with compressor and pulley operation
    -

    OK:
    The display is as specified in the normal condition column.


    Result:

    Result
    Proceed to
    NG
    A
    OK (Checking from the PROBLEM SYMPTOMS TABLE)
    B
    OK (Checking from the DTC)
    C



B
PROCEED TO NEXT CIRCUIT INSPECTION SHOWN IN PROBLEM SYMPTOMS TABLE

C
REPLACE AIR CONDITIONING AMPLIFIER
A


2.INSPECT COMPRESSOR AND PULLEY
E115015E05
  1. Disconnect the C8 compressor and pulley connector.

  1. Measure the resistance.

    Standard resistance:
    Tester Connection
    Specified Condition
    C8-1 - C8-2
    10.1 to 11.1 Ω at 25°C (77°F)

  1. Reconnect the compressor and pulley connector.



NG
REPLACE COMPRESSOR AND PULLEY
OK


3.CHECK HARNESS AND CONNECTOR (COMPRESSOR AND PULLEY - AIR CONDITIONING AMPLIFIER)
E142752E01
  1. Disconnect the C8 compressor and pulley connector.

  1. Disconnect the E8 air conditioning amplifier connector.

  1. Measure the resistance.

    Standard resistance:
    Tester Connection
    Specified Condition
    C8-1 - E8-7 (SOL+)
    Below 1 Ω
    C8-1 - Body ground
    1 MΩ or higher

  1. Reconnect the compressor and pulley connector.

  1. Reconnect the air conditioning amplifier connector.



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK


4.CHECK HARNESS AND CONNECTOR (COMPRESSOR AND PULLEY - BODY GROUND)
E119774E01
  1. Disconnect the C8 compressor and pulley connector.

  1. Measure the resistance.

    Standard resistance:
    Tester Connection
    Specified Condition
    C8-2 - Body ground
    Below 1 Ω

  1. Reconnect the compressor and pulley connector.



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK

REPLACE AIR CONDITIONING AMPLIFIER