DTC B1451/51 Compressor Solenoid Circuit |
| DTC No. | DTC Detection Condition | Trouble Area |
| B1451/51 | Open or short in solenoid of externally changeable compressor circuit |
|

| 1.READ VALUE USING INTELLIGENT TESTER (REG CTRL CURRNT) |
Connect the intelligent tester to the DLC3.
Turn the ignition switch on (IG) and turn the intelligent tester main switch ON.
Select the items below in the Data List, and read the value displayed on the intelligent tester.
| ITEM | Measurement Item / Display (Range) | Normal Condition | Diagnostic Note |
| Reg Ctrl Currnt | Regulator control current / Min.: 0 A MAX.: 0.997 A | Value changes between 0 A and 0.997 A in accordance with compressor and pulley operation | - |
| Result | Proceed to |
| NG | A |
| OK (Checking from the PROBLEM SYMPTOMS TABLE) | B |
| OK (Checking from the DTC) | C |
|
| ||||
|
| ||||
| A | |
| 2.INSPECT COMPRESSOR AND PULLEY |
![]() |
Disconnect the C8 compressor and pulley connector.
Measure the resistance.
| Tester Connection | Specified Condition |
| C8-1 - C8-2 | 10.1 to 11.1 Ω at 25°C (77°F) |
Reconnect the compressor and pulley connector.
|
| ||||
| OK | |
| 3.CHECK HARNESS AND CONNECTOR (COMPRESSOR AND PULLEY - AIR CONDITIONING AMPLIFIER) |
![]() |
Disconnect the C8 compressor and pulley connector.
Disconnect the E8 air conditioning amplifier connector.
Measure the resistance.
| Tester Connection | Specified Condition |
| C8-1 - E8-7 (SOL+) | Below 1 Ω |
| C8-1 - Body ground | 1 MΩ or higher |
Reconnect the compressor and pulley connector.
Reconnect the air conditioning amplifier connector.
|
| ||||
| OK | |
| 4.CHECK HARNESS AND CONNECTOR (COMPRESSOR AND PULLEY - BODY GROUND) |
![]() |
Disconnect the C8 compressor and pulley connector.
Measure the resistance.
| Tester Connection | Specified Condition |
| C8-2 - Body ground | Below 1 Ω |
Reconnect the compressor and pulley connector.
|
| ||||
| OK | ||
| ||