Home › SERVICE SPECIFICATIONS › SERVICE SPECIFICATIONS › 1NZ-FE CHARGING

1NZ-FE CHARGING > SERVICE DATA



Battery
Standard specific gravity:
1.25 to 1.29 at 20°C (68°F)
Charging circuit without load
Standard amperage
10 A or less
Standard voltage
13.2 to 14.8 V
Charging circuit with load
Standard amperage
30 A or more
Generator brush holder assembly brush exposed length
Standard exposed length
9.5 to 11.5mm (0.374 to 0.453 in.)
Minimum exposed length
1.5mm (0.059 in.)
Generator regulator assembly resistance
F-B
When the positive and negative poles between terminals F and B are exchanged, there is continuity in one direction but no continuity in the other direction.
F-E
When the positive and negative poles between terminals F and E are exchanged, there is continuity in one direction but no continuity in the other direction.
Generator drive end frame resistance
Coil wires
Below 1Ω
Coil wire and body
10kΩ or higher
Generator holder with rectifier resistance
P1, P2, P3 -B
When the positive and negative poles among terminals P1, P2, P3 and B are exchanged, there is continuity in one direction but on continuity in the other direction.
P1, P2, P3 -E
When the positive and negative poles among terminals P1, P2, P3 and E are exchanged, there is continuity in one direction but on continuity in the other direction.
Generator rotor assembly resistance
Slip rings
1.7 to 2.1Ω at 20°C (68°F)
Slip ring and rotor
10kΩ or higher
Generator rotor assembly slip ring diameter
Standard diameter
14.2 to 14.4mm (0.559 to 0.567 in.)
Minimum diameter
12.8 mm (0.504 in.)