AIR CONDITIONING SYSTEM > DETAILS



FUNCTION OF MAIN COMPONENTS
  1. The air conditioning system consists of the following parts:

    Component
    Function
    Air Conditioning Control Assembly*1
    Allows operation and adjustment of the air conditioning system via switches.
    No. 1 Heater Control Sub-assembly*2
    Allowing the A/C switch to be turned on or off manually and the air outlet temperature to be adjusted manually.*3
    Allows the air outlet to be adjusted manually.*4
    No. 2 Heater Control Sub-assembly*2
    Allows the blower control and the fresh-air/recirculation mode to be selected manually.
    No. 3 Heater Control Sub-assembly*2
    Allows the A/C switch to be turned on or off manually and the air outlet temperature to be adjusted manually.
    Air Conditioning Amplifier Assembly
    Transmits and receives data between the switches and sensors.
    Compressor with Pulley Assembly
    A continuously variable capacity type cooler compressor is used to steplessly control the refrigerant discharge capacity, thus improving comfort and achieving energy savings.
    Blower with Fan Motor Assembly
    High magnetic force magnets and ball bearings are used to achieve a compact and lightweight assembly.
    Cooler Condenser Assembly
    A Multi-Flow (MF)-IV sub-cool condenser is used to improve heat exchange efficiency.
    Heater Radiator Unit Sub-assembly
    A Straight Flow Aluminum (SFA)-II heater radiator is used for compactness and high performance.
    No. 1 Cooler Evaporator Sub-assembly
    A Revolutionary super-Slim structure (RS) evaporator is used for compactness.
    No. 1 Cooler Thermistor
    Detects the temperature of the cool air past the No. 1 cooler evaporator sub-assembly and transmits the data to the air conditioning amplifier assembly.
    Thermistor Assembly
    Detects ambient temperature and outputs it to the air conditioning amplifier assembly.
    Cooler (Room Temperature Sensor) Thermistor*1
    Detects room temperature and outputs it to the air conditioning amplifier assembly.
    Automatic Light Control Sensor*1
    Detects the changes in the amount of solar energy and outputs them to the air conditioning amplifier assembly.
    Air Mix Servo Motor (No. 1 Air Conditioning Radiator Damper Servo Sub-assembly)*1
    Receives the input of temperature setting dial signals via the air conditioning amplifier assembly, operates the motor, and opens and closes the air mix damper.
    Air Inlet Servo Motor (No. 1 Blower Damper Servo Sub-assembly)*1
    Receives the input of the operation signals from the fresh-air/recirculation selector switch via the air conditioning amplifier assembly, operates the motor, and opens and closes the fresh-air/recirculation damper.
    Air Outlet Servo Motor (No. 2 Air Conditioning Radiator Damper Servo Sub-assembly)*1
    Receives the input of the operation signals from the mode selector switch via the air conditioning amplifier assembly, operates the motor, and opens and closes the mode damper.
    Clean Air Filter
    Removes particles to provide a comfortable interior space.
    Air Conditioning Pressure Sensor
    Detects the refrigerant pressure and sends the data to the air conditioning amplifier assembly.
    E.F.I. Engine Coolant Temperature Sensor
    Detects the engine coolant temperature and transmits it to the ECM.
    ECM
    Receives the signals from the E.F.I. engine coolant temperature sensor and transmits them to the air conditioning amplifier assembly.

    1. *1: Models with automatic air conditioning system
    2. *2: Models with manual air conditioning system
    3. *3: Models without boost vent
    4. *4: Models with boost vent


SYSTEM CONTROL
  1. Control List

    1. The air conditioning system uses the following types of control.

      Control
      Outline
      Air Conditioning Type
      Automatic
      Manual
      Neural Network Control
      This control is capable of effecting complex control by artificially simulating the information processing method of the nervous system of living organisms in order to establish a complex input or output relationship that is similar to a human brain.
      ○
      -
      Outlet Air Temperature Control
      In compliance with the temperature set at the temperature control switch, the neural network control calculates the outlet temperature based on the input signals from various sensors. In addition, corrections in accordance with the signals from the No. 1 cooler thermistor and the E.F.I. engine coolant temperature sensor are added to control the outlet air temperature.
      ○
      -
      Blower Control
      Controls the blower with fan motor sub-assembly in accordance with the airflow volume that has been calculated by the neural network control based on the input signals from various sensors.
      ○
      -
      Air Outlet Control
      Automatically switches the outlets in accordance with the outlet mode ratio that has been calculated by the neural network control based on the input signals from various sensors.
      ○
      -
      Air Inlet Control
      Automatically controls the air inlet control damper in accordance with the airflow volume that has been calculated by the neural network control.
      ○
      -
      Refrigerant Volume Detection Control
      Judges a shortage of refrigerant volume based on signals from each sensor and informs the user by turning off the indicator light of the A/C switch.
      ○
      ○
      Variable Capacity Compressor Control
      Controls the compressor with pulley assembly to turn on or off and the discharge capacity based on the signals from various sensors.
      ○
      ○
      Self-diagnosis
      The air conditioning amplifier assembly has a self-diagnosis function. It stores any operation failures in the memory in the form of a Diagnostic Trouble Code (DTC).
      ○
      ○

      1. ○: Equipped
      2. -: Not equipped



  2. Neural Network Control

    1. Previously, in automatic air conditioning systems without neural network control, the air conditioning amplifier assembly determined the required outlet air temperature and blower air volume in accordance with the calculation formula that has been obtained based on information received from the sensors. However, because the senses of a person are rather complex, a given temperature is sensed differently, depending on the environment in which the person is situated. For example, a given amount of solar radiation can feel comfortably warm in a cold climate, or extremely uncomfortable in a hot climate. Therefore, as a technique for effecting a higher level of control, a neural network has been adopted in the automatic air conditioning system. With this technique, the data that has been collected under varying environmental conditions is stored in the air conditioning amplifier assembly. The air conditioning amplifier assembly can then effect control to provide enhanced air conditioning comfort.



    2. The neural network control consists of neurons in the input layer, intermediate layer and output layer. The input layer neurons process the input data of the ambient temperature, the amount of sunlight, and the room temperature based on the outputs of the switches and sensors, and output them to the intermediate layer neurons. Based on this data, the intermediate layer neurons adjust the strength of the links among the neurons. The sum of these is then calculated by the output layer neurons in the form of the required outlet temperature, solar correction, target airflow volume, and outlet mode control volume. Accordingly, the air conditioning amplifier assembly controls the servo motors and blower motor in accordance with the control volumes that have been calculated by the neural network control.


      Y111168E01



  3. Refrigerant Volume Detection Control



    1. The air conditioning amplifier assembly judges the volume of refrigerant from the ambient temperature, refrigerant pressure and the temperature of the cool air past the No. 1 cooler evaporator sub-assembly. When the air conditioning amplifier assembly judges refrigerant shortage, it turns off the indicator light of the A/C switch. At that time, the compressor with pulley assembly stops operating.


      Y112436E01


CONSTRUCTION


  1. Heater Control Sub-assemblies (Models with Manual Air Conditioning System)

    1. A rotary switch type heater control sub-assemblies is used.



    2. 5 air outlet modes are provided on the control panel. To enable finer mode settings, a positive feel is provided between the positions of these modes, thus achieving a high comfort level.


      Y111152E01


      Text in Illustration 
      *A
      Models without Boost Vent
      *B
      Models with Boost Vent
      *1
      No. 1 Heater Control Sub-assembly
      *2
      No. 2 Heater Control Sub-assembly
      *3
      No. 3 Heater Control Sub-assembly
      -
      -

    3. A control cable is used. This cable is circular, and is placed around the cable pulleys that are provided at the heater control sub-assembly and the damper.



    4. The operation effort of the heater control sub-assembly is transmitted to the damper via the control cable, which always moves in the pulling direction. Due to the consistent action point of the pulleys, the fluctuation of the operating effort has been minimized through the use of the pulleys. These measures have ensured ease of use and have reduced the operating effort.


      Y108971E01


      Text in Illustration 
      *1
      Pulley
      *2
      Base of Pulley
      *3
      Control Cable
      -
      -
      *a
      Heater Control Sub-assembly Side
      *b
      Damper Side



  2. Air Conditioning Control Assembly (Models with Automatic Air Conditioning System)

    1. A push button type air conditioning control assembly is used.



    2. An air conditioning control assembly with Liquid Crystal Display (LCD) is used to ensure excellent visibility.


      Y111155E01


      Text in Illustration 
      *1
      LCD
      -
      -



  3. Air Conditioning Unit Assembly

    1. The air conditioning unit consists of the heater radiator unit sub-assembly, No. 1 cooler evaporator sub-assembly, No. 1 cooler thermistor and damper servo sub-assemblies.



    2. A semi-center location air conditioning unit, in which the heater radiator unit sub-assembly and No. 1 cooler evaporator sub-assembly are placed in the vehicle's longitudinal direction, is used.


      Y111294E01


      Text in Illustration 
      *1
      No. 1 Cooler Evaporator Sub-assembly
      *2
      Heater Radiator Unit Sub-assembly
      *a
      Side View
      *b
      Top View
      V100135
      Front
      -
      -



    3. A partial recirculation system is used. This system has an air inlet control door (sub) in the air inlet duct. Thus, it is able to cycle a small volume of recirculated air even in the FRESH mode, thus enhancing heating performance. When the blower switch is on, the suction force of the blower fan opens this air inlet control door (sub).


      Y111169E01


      Text in Illustration 
      *1
      Air Inlet Control Door (Sub)
      *2
      Air Inlet Control Door
      *3
      Air Inlet Duct
      -
      -
      *a
      RECIRC
      *b
      FRESH
      *c
      To Blower Fan
      -
      -
      V100135
      Air Flow
      V100136
      Front



  4. No. 1 Cooler Evaporator Sub-assembly



    1. A Revolutionary super-Slim structure (RS) evaporator is used. By placing the tanks at the top and the bottom of the No. 1 cooler evaporator sub-assembly and by using a micropore tube construction, the following effects have been achieved:

      1. Heat exchanging efficiency is ensured.
      2. Temperature distribution is made uniform.
      3. The No. 1 cooler evaporator sub-assembly is made thinner.

      Y108975E01


      Text in Illustration 
      *1
      Tank
      *2
      Micropore Tube
      *3
      Cooling Fin
      -
      -

  5. No. 1 Cooler Thermistor

    1. The No. 1 cooler thermistor detects the temperature of the cool air immediately past the No. 1 cooler evaporator sub-assembly in the form of resistance changes, and outputs it to the air conditioning amplifier assembly.



  6. Heater Radiator Unit Sub-assembly



    1. The heater radiator unit sub-assembly has been made more compact and performance has been improved by making the core section finer and improving the shapes of the tank section and flow section. Also, the environment has been considered. By using aluminum as the material, the amount of the environmental burden disposal (lead) has been reduced.


      Y108976

  7. Blower with Fan Motor Sub-assembly

    1. High magnetic force magnets and ball bearings are used to achieve a compact and lightweight assembly.



  8. Bus Connector (Air Conditioning Harness Assembly)



    1. The bus connector (air conditioning harness assembly) has a built-in communication/driver IC, which communicates with each servo motor connector, actuates the servo motor, and has a position detection function. This enables bus communication for the servo motor wire harness to achieve a more lightweight construction and a reduced number of wires.


      Y111170E01



  9. Servo Motor

    1. In contrast to the previous type that detects the position by way of a potentiometer voltage, the pulse pattern type servo motor detects the relative position by way of the 2-bit on/off signals.



    2. The forward and reverse revolutions of this motor are detected by way of 2 phases, A and B, which output 4 types of patterns. The air conditioning amplifier assembly counts the number of pulse patterns in order to determine the stopped position.


      Y111171E01



  10. Cooler Condenser Assembly

    1. A sub-cool condenser is used. This is a multi-flow condenser consisting of 3 portions: a condensing portion, a super-cooling portion and a gas-liquid separator (modulator) all integrated together. This cooler condenser assembly uses a sub-cool cycle for its cooling cycle system to improve heat-exchanging efficiency.



    2. In the sub-cool cycle, after the refrigerant passes through the condensing portion of the cooler condenser assembly, both the liquid refrigerant and the gaseous refrigerant that could not be liquefied are cooled again in the super-cooling portion. Thus, the refrigerant is sent to the No. 1 cooler evaporator sub-assembly in an almost completely liquefied state.


      Y108979E01


      Text in Illustration 
      *1
      Modulator
      *2
      Desiccant
      *3
      Filter
      *4
      Super-cooling Portion
      *5
      Condensing Portion
      -
      -
      V100135
      Gaseous Refrigerant
      V100136
      Liquid Refrigerant

      HINT:
      The point at which the air bubbles disappear in the refrigerant of the sub-cool cycle is lower than the proper amount of refrigerant with which the system must be filled. Therefore, if the system were recharged with refrigerant based on the point at which the air bubbles disappear, the amount of refrigerant would be insufficient. As a result, the cooling performance of the system will be affected. If the system is overcharged with refrigerant, this will also lead to reduced performance. For the proper method of verifying the amount of the refrigerant and to recharge the system with refrigerant, refer to the Repair Manual.


      Y100720E02



  11. Compressor with Pulley Assembly

    1. The compressor with pulley assembly is a continuously variable capacity type with a capacity that varies in accordance with the cooling load of the air conditioning.



    2. The compressor with pulley assembly consists of the shaft, lug plate, piston, shoe, crank chamber, cylinder and solenoid control valve.


      Y111821E01


      Text in Illustration 
      *1
      Shoe
      *2
      Crank Chamber
      *3
      Shaft
      *4
      Lug Plate
      *5
      Piston
      *6
      Cylinder
      *7
      Solenoid Control Valve
      -
      -



    3. A variable suction side throttle is used.

      1. Refrigerant inlet pressure is applied to the top of the variable suction side throttle and crank chamber pressure to the bottom of the variable suction side throttle.
      2. The pressure difference moves the variable suction side throttle up and down, expanding and contracting the refrigerant inlet passage.
      3. When the refrigerant flow is at a maximum, the refrigerant inlet pressure is greater than the crank chamber pressure. This causes the variable suction side throttle to move down, fully opening the refrigerant inlet passage and lowering the refrigerant inlet resistance.
      4. When the amount of refrigerant flow is controlled, the crank chamber pressure is greater than the refrigerant inlet pressure, raising the variable inlet throttle to contract the flow passage.
      5. These controls suppress noise by reducing pulsation from the refrigerant inlet.

      Y111822E01


      Text in Illustration 
      *A
      Maximum Volume of Refrigerant
      *B
      Controlled Volume of Refrigerant
      *1
      Refrigerant Passage A
      *2
      Inlet Chamber
      *3
      Variable Suction Side Throttle
      *4
      Crank Pressure Inlet Chamber
      *5
      Compressor with Pulley Assembly
      -
      -
      *a
      High Flow
      *b
      Low Flow
      V100135
      Crank Chamber Pressure
      V100136
      Refrigerant Flow



    4. A Damper Limiter (DL) type air conditioning pulley is used. A cylinder-type damper is used for this compressor with pulley assembly and the torque fluctuations have been suppressed, thus making the inertia weight unnecessary. As a result, the weight of the compressor with pulley assembly has been reduced.


      Y111823E01


      Text in Illustration 
      *A
      5TSE10C Compressor
      *B
      Conventional Type Compressor
      *1
      Damper
      *2
      Inertia Weight



  12. Clean Air Filter



    1. A high efficiency type clean air filter is used to remove dust and other micron particles from air entering from outside the vehicle to provide a comfortable cabin of clean air. The clean air filter is installed in the upper section of the blower with fan motor assembly.


      Y111156E01


      Text in Illustration 
      *1
      Blower with Fan Motor Assembly
      *2
      Clean Air Filter
      *3
      Air Filter Case
      -
      -

      HINT:
      See the table below regarding the replacement intervals for the clean air filter. Replace the clean air filter after the ignition switch has been turned off.

      Destination
      Replacement Interval
      Australia
      Normal Condition : 30000 km (18000 miles)
      Dusty Condition : 15000 km (9000 miles)
      G.C.C. Countries, General Countries
      Normal Condition : 20000 km (12000 miles)
      Dusty Condition : 15000 km (9000 miles)

  13. Thermistor Assembly

    1. The thermistor assembly detects the ambient temperature based on changes in the resistance of its built-in thermistor. This signal is used by the air conditioning amplifier assembly.

  14. Cooler (Room Temperature Sensor) Thermistor

    1. The cooler (room temperature sensor) thermistor detects the room temperature based on changes in the resistance of its built-in thermistor. This signal is used by the air conditioning amplifier assembly.

  15. Automatic Light Control Sensor

    1. The automatic light control sensor detects (in the form of changes in the current that flows through the built-in photo diode) the changes in the amount of sunlight and outputs these sunlight strength signals to the air conditioning amplifier assembly.


OPERATION


  1. Mode Position and Door Operation



    1. Models without Boost Vent


      Y111173E01

      HINT:
      This illustration is a model diagram showing the doors positions in each mode. The parts layout and the number of the doors in the illustration are different from those of the actual system.


      Control Damper
      Operation Position
      Damper Position
      Operation
      Air Inlet
      FRESH
      A
      Brings in fresh air.
      RECIRCULATION
      B
      Recirculates internal air.
      Air Mix
      MAX COLD to MAX HOT
      C to D
      Varies the mixture ratio of the fresh air and the recirculation air in order to regulate the temperature continuously from HOT to COLD.
      Mode
      Y100734
      FACE
      E, J
      Air blows out of the center register and side register.
      Y100733
      BI-LEVEL
      F, J
      Air blows out of the center register, side registers and front footwell register ducts.
      Y100732
      FOOT
      F, I
      Air blows out of the front footwell register ducts and side register. In addition, air blows out slightly from the front defroster and side defroster.
      Y100731
      FOOT/DEF
      F, H
      Defrosts the windshield through the center defroster, side defroster and side register, while air is also blown out from the front footwell register ducts.
      Y100730
      DEF
      E, G
      Defrosts the windshield through the center defroster, side defroster and side register.



    2. Models with Boost Vent


      Y111174E01

      HINT:
      This illustration is a model diagram showing the doors positions in each mode. The parts layout and the number of the doors in the illustration are different from those of the actual system.


      Control Damper
      Operation Position
      Damper Position
      Operation
      Air Inlet
      FRESH
      A
      Brings in fresh air.
      RECIRCULATION
      B
      Recirculates internal air.
      Mode
      Y100734
      FACE
      C
      Air blows out of the center register and side register.
      Y100733
      BI-LEVEL
      D
      Air blows out of the center register, side registers and front footwell register ducts.



  2. Air Outlets and Airflow Volume



    1. Models without Boost Vent


      Y111990E01


      Indication
      Mode
      A
      B
      C
      D
      Center
      Side
      Foot
      Defroster
      Y100734
      FACE
      Y108997
      Y108997
      -
      -
      Y100733
      BI-LEVEL
      Y108996
      Y108996
      Y108997
      -
      Y100732
      FOOT
      -
      Y108995
      Y108997
      Y108995
      Y100731
      FOOT/DEF
      -
      Y108995
      Y108996
      Y108996
      Y100730
      DEF
      -
      Y108996
      -
      Y108997

      HINT:
      The size of the circle ○ indicates the proportion of airflow volume.



    2. Models with Boost Vent


      Y111824E01


      Indication
      Mode
      A
      B
      C
      Center
      Side
      Foot
      Y100734
      FACE
      Y108997
      Y108997
      -
      Y100733
      BI-LEVEL
      Y108996
      Y108996
      Y108997

      HINT:
      The size of the circle ○ indicates the proportion of airflow volume.



  3. Compressor Operation

    1. The crank chamber is connected to the suction passage. A solenoid control valve is provided between the suction passage (low pressure) and the discharge passage (high pressure).



    2. The solenoid control valve operates under duty cycle control in accordance with the signals from the air conditioning amplifier assembly.


      Y108998E01


      Text in Illustration 
      *1
      Suction Passage
      *2
      Crank Chamber
      *3
      Piston
      *4
      Discharge Passage
      *5
      Solenoid Control Valve
      *6
      Air Conditioning Amplifier Assembly



    3. When the solenoid control valve closes (the solenoid coil is energized), a difference in pressure is created and the pressure in the crank chamber decreases. Then, the pressure applied to the right side of the piston becomes greater than the pressure applied to the left side of the piston. This compresses the spring and tilts the lug plate. As a result, the piston stroke increases and the discharge capacity increases.


      Y108999E01


      Text in Illustration 
      *1
      Suction Passage
      *2
      Crank Chamber
      *3
      Piston
      *4
      Discharge Passage
      *5
      Solenoid Control Valve
      *6
      Air Conditioning Amplifier Assembly
      *a
      Crank Chamber Pressure + Spring Force
      *b
      Piston Stroke: Large



    4. When the solenoid control valve opens (the solenoid coil is not energized), the difference in pressure disappears. Then, the pressure applied to the left side of the piston becomes the same as the pressure applied to the right side of the piston. Thus, the spring elongates and eliminates the tilt of the lag plate. As a result, there is a small piston stroke and the discharge capacity decreases.


      Y109000E01


      Text in Illustration 
      *1
      Suction Passage
      *2
      Crank Chamber
      *3
      Piston
      *4
      Discharge Passage
      *5
      Solenoid Control Valve
      *6
      Air Conditioning Amplifier Assembly
      *a
      Crank Chamber Pressure + Spring Force
      *b
      Piston Stroke: Small


DIAGNOSIS
  1. The air conditioning amplifier assembly has a self-diagnosis function. It stores any operation failures in the air conditioning system memory in the form of DTCs. For details, refer to the Repair Manual.