Home › Vehicle Interior › HEATING / AIR CONDITIONING › AIR CONDITIONING SYSTEM (for Manual Air Conditioning System)

AIR CONDITIONING SYSTEM (for Manual Air Conditioning System) > DATA LIST / ACTIVE TEST

for Preparation Click here



DATA LIST (w/ Cooler)

HINT:
Using the intelligent tester to read the Data List allows the values or states of switches, sensors, actuators and other items to be read without removing any parts. This non-intrusive inspection can be very useful because intermittent conditions or signals may be discovered before parts or wiring is disturbed. Reading the Data List information early in troubleshooting is one way to save diagnostic time.

NOTICE:
In the table below, the values listed under "Normal Condition" are reference values. Do not depend solely on these reference values when deciding whether a part is faulty or not.

  1. Connect the intelligent tester to the DLC3.

  2. Turn the ignition switch to ON.

  3. Turn the intelligent tester on.

  4. Enter the following menus: Body / Air Conditioner / Data List.

  5. According to the display on the intelligent tester, read the Data List.

    Air Conditioner 
    Tester Display
    Measurement Item/Range
    Normal Condition
    Diagnostic Note
    Ambient Temp Sensor
    Ambient temperature sensor /
    Min.: -23.3°C (-9.94°F)
    Max.: 65.95°C (150.71°F)
    Actual ambient temperature is displayed
    -
    Adjusted Ambient Temp
    Adjusted ambient temperature /
    Min.: -30.8°C (-23.44°F)
    Max.: 50.8°C (123.44°F)
    -
    -
    Evaporator Fin Thermistor
    Evaporator temperature sensor /
    Min.: -29.7°C (-21.46°F)
    Max.: 59.55°C (139.19°F)
    Actual evaporator temperature displayed
    Open in the circuit: -29.7°C (-21.46°F).
    Short in the circuit: 59.55°C (139.19°F).
    Evaporator Target Temp
    Target evaporator temperature /
    Min.: -327.68°C (-557.82°F)
    Max.: 327.67°C (621.81°F)
    Target evaporator temperature displayed
    -
    Engine Coolant Temp
    Engine coolant temperature /
    Min.: 1.3°C (34.34°F)
    Max.: 90.55°C (194.99°F)
    Actual engine coolant temperature is displayed after engine warmed up
    -
    Regulator Pressure Sensor
    Regulator pressure sensor /
    Min.: -0.4566 MPaG
    Max.: 3.2943 MPaG
    Actual regulator pressure is displayed
    -
    Regulator Control Current
    Regulator control current /
    Min.: 0 A
    Max.: 0.997 A
    Value changes between 0.12 A and 0.997 A in accordance with compressor operation
    -
    Refrigerant Shortage Check
    Refrigerant shortage check function /
    ON or OFF
    Customized value displayed
    -
    A/C Cutoff Signal
    A/C control cutoff signal /
    ON or OFF
    -
    -
    Number of Trouble Codes
    Number of trouble codes /
    Min.: 0
    Max.: 255
    Number of DTCs displayed
    -


ACTIVE TEST (w/ Cooler)

HINT:
Using the intelligent tester to perform Active Tests allows relays, VSVs, actuators and other items to be operated without removing any parts. This non-intrusive functional inspection can be very useful because intermittent operation may be discovered before parts or wiring is disturbed. Performing Active Tests early in troubleshooting is one way to save diagnostic time. Data List information can be displayed while performing Active Tests.

  1. Connect the intelligent tester to the DLC3.

  2. Turn the ignition switch to ON.

  3. Turn the intelligent tester on.

  4. Enter the following menus: Body / Air Conditioner / Active Test.

  5. According to the display on the intelligent tester, perform the Active Test.

    Air Conditioner 
    Tester Display
    Test Part
    Control Range
    Diagnostic Note
    Magnetic Clutch Relay
    A/C Compressor
    OFF or ON
    -