Home › Vehicle Exterior › WINDOW / GLASS › POWER WINDOW MASTER SWITCH

POWER WINDOW MASTER SWITCH > INSPECTION

for Preparation Click here



1. INSPECT POWER WINDOW REGULATOR MASTER SWITCH ASSEMBLY (w/ Rear Power Window)


  1. for LHD:



    1. Measure the resistance according to the value(s) in the table below.


      B284402E01


      Text in Illustration 
      *1
      Driver Switch
      *2
      Front Passenger Switch
      *3
      Rear RH Side Switch
      *4
      Rear LH Side Switch
      *5
      Window Lock Switch
      *6
      Illumination
      *a
      Component without harness connected
      (Power Window Regulator Master Switch Assembly)
      -
      -

      Standard Resistance:

      Driver Switch 
      Tester Connection
      Window Lock Switch Condition
      Power Window Switch Condition
      Specified Condition
      8(UP) - 1(GND) - 4(AUTO)
      5(DOWN) - 6(B)
      Always (ON/OFF)
      UP AUTO
      Below 1 Ω
      8(UP) - 1(GND)
      5(DOWN) - 6(B)
      Always (ON/OFF)
      UP MANUAL
      Below 1 Ω
      8(UP) - 5(DOWN) - 6(B)
      Always (ON/OFF)
      OFF
      Below 1 Ω
      5(DOWN) - 1(GND)
      8(UP) - 6(B)
      Always (ON/OFF)
      DOWN MANUAL
      Below 1 Ω
      4(AUTO) - 5(DOWN) - 1(GND)
      8(UP) - 6(B)
      Always (ON/OFF)
      DOWN AUTO
      Below 1 Ω


      Standard Resistance:

      Passenger Side Switch 
      Tester Connection
      Window Lock Switch Condition
      Power Window Switch Condition
      Specified Condition
      6(B) - 16(U)
      1(GND) - 15(D)
      OFF
      UP
      Below 1 Ω
      1(GND) - 16(U)
      1(GND) - 15(D)
      OFF
      OFF
      Below 1 Ω
      1(GND) - 16(U)
      6(B) - 15(D)
      OFF
      DOWN
      Below 1 Ω
      6(B) - 16(U)
      ON
      UP
      Below 1 Ω
      16(U) - 15(D)
      ON
      OFF
      Below 1 Ω
      6(B) - 15(D)
      ON
      DOWN
      Below 1 Ω


      Standard Resistance:

      Rear RH Side Switch 
      Tester Connection
      Window Lock Switch Condition
      Power Window Switch Condition
      Specified Condition
      6(B) - 10(U)
      1(GND) - 18(D)
      OFF
      UP
      Below 1 Ω
      1(GND) - 18(D)
      1(GND) - 10(U)
      OFF
      OFF
      Below 1 Ω
      6(B) - 18(D)
      1(GND) - 10(U)
      OFF
      DOWN
      Below 1 Ω
      6(B) - 10(U)
      ON
      UP
      Below 1 Ω
      18(D) - 10(U)
      ON
      OFF
      Below 1 Ω
      6(B) - 18(D)
      ON
      DOWN
      Below 1 Ω


      Standard Resistance:

      Rear LH Side Switch 
      Tester Connection
      Window Lock Switch Condition
      Power Window Switch Condition
      Specified Condition
      6(B) - 12(U)
      1(GND) - 13(D)
      OFF
      UP
      Below 1 Ω
      1(GND) - 13(D)
      1(GND) - 12(U)
      OFF
      OFF
      Below 1 Ω
      6(B) - 13(D)
      1(GND) - 12(U)
      OFF
      DOWN
      Below 1 Ω
      6(B) - 12(U)
      ON
      UP
      Below 1 Ω
      13(D) - 12(U)
      ON
      OFF
      Below 1 Ω
      6(B) - 13(D)
      ON
      DOWN
      Below 1 Ω

      If the result is not as specified, replace the power window regulator master switch assembly.

    2. Apply battery voltage to the power window regulator master switch and check that the illumination comes on.

      OK:
      Measurement Condition
      Specified Condition
      Battery positive (+) → Terminal 3(LED)
      Battery negative (-) → Terminal 1(GND)
      Illumination comes on

      If the result is not as specified, replace the power window regulator master switch assembly.



  1. for RHD:



    1. Measure the resistance according to the value(s) in the table below.


      B140038E01


      Text in Illustration 
      *1
      Driver Switch
      *2
      Front Passenger Switch
      *3
      Rear RH Side Switch
      *4
      Rear LH Side Switch
      *5
      Window Lock Switch
      *6
      Illumination
      *a
      Component without harness connected
      (Power Window Regulator Master Switch Assembly)
      -
      -

      Standard Resistance:

      Driver Switch 
      Tester Connection
      Window Lock Switch Condition
      Power Window Switch Condition
      Specified Condition
      1(UP) - 9(GND) - 4(AUTO)
      5(DOWN) - 6(B)
      Always (ON/OFF)
      UP AUTO
      Below 1 Ω
      1(UP) - 9(GND)
      5(DOWN) - 6(B)
      Always (ON/OFF)
      UP MANUAL
      Below 1 Ω
      1(UP) - 5(DOWN) - 6(B)
      Always (ON/OFF)
      OFF
      Below 1 Ω
      5(DOWN) - 9(GND)
      1(UP) - 6(B)
      Always (ON/OFF)
      DOWN MANUAL
      Below 1 Ω
      4(AUTO) - 5(DOWN) - 9(GND)
      1(UP) - 6(B)
      Always (ON/OFF)
      DOWN AUTO
      Below 1 Ω


      Standard Resistance:

      Passenger Side Switch 
      Tester Connection
      Window Lock Switch Condition
      Power Window Switch Condition
      Specified Condition
      6(B) - 12(U)
      9(GND) - 13(D)
      OFF
      UP
      Below 1 Ω
      9(GND) - 12(U)
      9(GND) - 13(D)
      OFF
      OFF
      Below 1 Ω
      9(GND) - 12(U)
      6(B) - 13(D)
      OFF
      DOWN
      Below 1 Ω
      6(B) - 12(U)
      ON
      UP
      Below 1 Ω
      12(U) - 13(D)
      ON
      OFF
      Below 1 Ω
      6(B) - 13(D)
      ON
      DOWN
      Below 1 Ω


      Standard Resistance:

      Rear RH Side Switch 
      Tester Connection
      Window Lock Switch Condition
      Power Window Switch Condition
      Specified Condition
      6(B) - 16(U)
      9(GND) - 15(D)
      OFF
      UP
      Below 1 Ω
      9(GND) - 15(D)
      9(GND) - 16(U)
      OFF
      OFF
      Below 1 Ω
      6(B) - 15(D)
      9(GND) - 16(U)
      OFF
      DOWN
      Below 1 Ω
      6(B) - 16(U)
      ON
      UP
      Below 1 Ω
      15(D) - 16(U)
      ON
      OFF
      Below 1 Ω
      6(B) - 15(D)
      ON
      DOWN
      Below 1 Ω


      Standard Resistance:

      Rear LH Side Switch 
      Tester Connection
      Window Lock Switch Condition
      Power Window Switch Condition
      Specified Condition
      6(B) - 18(U)
      9(GND) - 10(D)
      OFF
      UP
      Below 1 Ω
      9(GND) - 10(D)
      9(GND) - 18(U)
      OFF
      OFF
      Below 1 Ω
      6(B) - 10(D)
      9(GND) - 18(U)
      OFF
      DOWN
      Below 1 Ω
      6(B) - 18(U)
      ON
      UP
      Below 1 Ω
      10(D) - 18(U)
      ON
      OFF
      Below 1 Ω
      6(B) - 10(D)
      ON
      DOWN
      Below 1 Ω

      If the result is not as specified, replace the power window regulator master switch assembly.

    2. Apply battery voltage to the power window regulator master switch and check that the illumination comes on.

      OK:
      Measurement Condition
      Specified Condition
      Battery positive (+) → Terminal 3(LED)
      Battery negative (-) → Terminal 9(GND)
      Illumination comes on

      If the result is not as specified, replace the power window regulator master switch assembly.



2. INSPECT POWER WINDOW REGULATOR MASTER SWITCH ASSEMBLY (w/o Rear Power Window)


  1. for LHD:



    1. Measure the resistance according to the value(s) in the table below.


      B284403E01


      Text in Illustration 
      *1
      Driver Switch
      *2
      Front Passenger Switch
      *3
      Window Lock Switch
      *4
      Illumination
      *a
      Component without harness connected
      (Power Window Regulator Master Switch Assembly)
      -
      -

      Standard Resistance:

      Driver Switch 
      Tester Connection
      Window Lock Switch Condition
      Power Window Switch Condition
      Specified Condition
      18(UP) - 7(GND) - 1(AUTO)
      10(DOWN) - 15(B)
      Always (ON/OFF)
      UP AUTO
      Below 1 Ω
      18(UP) - 7(GND)
      10(DOWN) - 15(B)
      Always (ON/OFF)
      UP MANUAL
      Below 1 Ω
      18(UP) - 10(DOWN) - 15(B)
      Always (ON/OFF)
      OFF
      Below 1 Ω
      10(DOWN) - 7(GND)
      18(UP) - 15(B)
      Always (ON/OFF)
      DOWN MANUAL
      Below 1 Ω
      1(AUTO) - 10(DOWN) - 7(GND)
      18(UP) - 15(B)
      Always (ON/OFF)
      DOWN AUTO
      Below 1 Ω


      Standard Resistance:

      Passenger Side Switch 
      Tester Connection
      Window Lock Switch Condition
      Power Window Switch Condition
      Specified Condition
      15(B) - 12(U)
      16(D) - 7(GND)
      OFF
      UP
      Below 1 Ω
      7(GND) - 12(U)
      7(GND) - 16(D)
      OFF
      OFF
      Below 1 Ω
      7(GND) - 12(U)
      15(B) - 16(D)
      OFF
      DOWN
      Below 1 Ω
      15(B) - 12(U)
      ON
      UP
      Below 1 Ω
      12(U) - 16(D)
      ON
      OFF
      Below 1 Ω
      15(B) - 16(D)
      ON
      DOWN
      Below 1 Ω

      If the result is not as specified, replace the power window regulator master switch assembly.

    2. Apply battery voltage to the power window regulator master switch and check that the illumination comes on.

      OK:
      Measurement Condition
      Specified Condition
      Battery positive (+) → Terminal 6(LED)
      Battery negative (-) → Terminal 7(GND)
      Illumination comes on

      If the result is not as specified, replace the power window regulator master switch assembly.



  1. for RHD:



    1. Measure the resistance according to the value(s) in the table below.


      B272687E01


      Text in Illustration 
      *1
      Driver Switch
      *2
      Front Passenger Switch
      *3
      Window Lock Switch
      *4
      Illumination
      *a
      Component without harness connected
      (Power Window Regulator Master Switch Assembly)
      -
      -

      Standard Resistance:

      Driver Switch 
      Tester Connection
      Window Lock Switch Condition
      Power Window Switch Condition
      Specified Condition
      9(UP) - 7(GND) - 18(AUTO)
      6(DOWN) - 15(B)
      Always (ON/OFF)
      UP AUTO
      Below 1 Ω
      9(UP) - 7(GND)
      6(DOWN) - 15(B)
      Always (ON/OFF)
      UP MANUAL
      Below 1 Ω
      9(UP) - 6(DOWN) - 15(B)
      Always (ON/OFF)
      OFF
      Below 1 Ω
      6(DOWN) - 7(GND)
      9(UP) - 15(B)
      Always (ON/OFF)
      DOWN MANUAL
      Below 1 Ω
      18(AUTO) - 6(DOWN) - 7(GND)
      9(UP) - 15(B)
      Always (ON/OFF)
      DOWN AUTO
      Below 1 Ω


      Standard Resistance:

      Passenger Side Switch 
      Tester Connection
      Window Lock Switch Condition
      Power Window Switch Condition
      Specified Condition
      15(B) - 12(U)
      10(D) - 7(GND)
      OFF
      UP
      Below 1 Ω
      7(GND) - 12(U)
      7(GND) - 10(D)
      OFF
      OFF
      Below 1 Ω
      7(GND) - 12(U)
      15(B) - 10(D)
      OFF
      DOWN
      Below 1 Ω
      15(B) - 12(U)
      ON
      UP
      Below 1 Ω
      12(U) - 10(D)
      ON
      OFF
      Below 1 Ω
      15(B) - 10(D)
      ON
      DOWN
      Below 1 Ω

      If the result is not as specified, replace the power window regulator master switch assembly.

    2. Apply battery voltage to the power window regulator master switch and check that the illumination comes on.

      OK:
      Measurement Condition
      Specified Condition
      Battery positive (+) → Terminal 16(LED)
      Battery negative (-) → Terminal 7(GND)
      Illumination comes on

      If the result is not as specified, replace the power window regulator master switch assembly.