AIR CONDITIONING SYSTEM (for Manual Air Conditioning System) > PRECAUTION |
| 1.IF ANY OF FOLLOWING CONDITIONS ARE MET, KEEP ENGINE IDLING WITH A/C ON (ENGINE SPEED AT LESS THAN 2000 RPM) FOR AT LEAST 1 MINUTE: |
| 2.DO NOT HANDLE REFRIGERANT IN AN ENCLOSED AREA OR NEAR AN OPEN FLAME |
![]() |
| *a | Charging Cylinder |
| 3.ALWAYS WEAR EYE PROTECTION |
| 4.BE CAREFUL NOT TO GET LIQUID REFRIGERANT IN YOUR EYES OR ON YOUR SKIN |
![]() |
Wash the area with lots of cold water.
Apply clean petroleum jelly to the skin.
Go immediately to a hospital or see a physician for professional treatment.
| 5.NEVER HEAT CONTAINER OR EXPOSE CONTAINER TO OPEN FLAME |
| 6.BE CAREFUL NOT TO DROP CONTAINER OR APPLY PHYSICAL SHOCKS TO IT |
| 7.DO NOT OPERATE COMPRESSOR WITHOUT ENOUGH REFRIGERANT IN REFRIGERANT SYSTEM |
| 8.DO NOT OPEN HIGH PRESSURE MANIFOLD VALVE WHILE COMPRESSOR IS OPERATING |
![]() |
Open and close only the low pressure valve. If the high pressure valve is opened, refrigerant flows in the reverse direction causing the charging cylinder to rupture.
| *a | Wrong |
| *b | Okay |
| 9.BE CAREFUL NOT TO OVERCHARGE SYSTEM WITH REFRIGERANT |
| 10.DO NOT OPERATE COMPRESSOR WITHOUT REFRIGERANT |