Home › Drivetrain · U340E AUTOMATIC TRANSMISSION / TRANSAXLE › VALVE BODY ASSEMBLY

VALVE BODY ASSEMBLY > INSPECTION

for Preparation Click here



1. INSPECT SHIFT SOLENOID VALVE S1


C155174E06
  1. Measure the resistance according to the value(s) in the table below.
    Text in Illustration 
    *a
    Component without harness connected
    (Shift Solenoid Valve S1)

    Standard Resistance:
    Tester Connection
    Condition
    Specified Condition
    Solenoid Connector (S1) - Solenoid Body (S1)
    20°C (68°F)
    11 to 15 Ω

    If the value is not as specified, replace the shift solenoid valve S1.

  1. Connect the positive (+) battery lead to the terminal of the solenoid connector, and the negative (-) battery lead to the solenoid body, and check the operation of the shift solenoid valve.

    NOTICE:
    While using the battery during the inspection, do not bring the positive and negative tester probes too close to each other as a short circuit may occur.

    OK:
    The solenoid makes an operating sound.

    If the operation cannot be done as specified, replace the shift solenoid valve S1.



2. INSPECT SHIFT SOLENOID VALVE S2

HINT:
Refer to Inspect Shift Solenoid Valve S1.



3. INSPECT SHIFT SOLENOID VALVE ST

HINT:
Refer to Inspect Shift Solenoid Valve S1.



4. INSPECT SHIFT SOLENOID VALVE SL

HINT:
Refer to Inspect Shift Solenoid Valve S1.



5. INSPECT SHIFT SOLENOID VALVE SLT


C155176E15
  1. Measure the resistance according to the value(s) in the table below.
    Text in Illustration 
    *a
    Component without harness connected
    (Shift Solenoid Valve SLT)

    Standard Resistance:
    Tester Connection
    Condition
    Specified Condition
    1 - 2
    20°C (68°F)
    5.0 to 5.6 Ω

    If the value is not as specified, replace the shift solenoid valve SLT.

  1. Connect the positive (+) battery lead with a 21 W bulb to terminal 2 and the negative (-) battery lead to terminal 1 of the solenoid valve connector, and check the operation of the shift solenoid valve.

    NOTICE:
    While using the battery during the inspection, do not bring the positive and negative tester probes too close to each other as a short circuit may occur.

    OK:
    The solenoid makes an operating sound.

    If the operation cannot be done as specified, replace the shift solenoid valve SLT.