POWER STEERING SYSTEM > DATA LIST / ACTIVE TEST |
| DATA LIST |
Turn the ignition switch off.
Connect the intelligent tester to the DLC3.
Start the engine.
Turn the tester on.
Enter the following menus: Chassis / EMPS / Data List.
According to the display on the tester, read the Data List.
| Tester Display | Measurement Item/Range | Normal Condition | Diagnostic Note |
| Meter Vehicle Velocity | Vehicle speed from meter/ Min.: 0.0 km/h (0 mph) Max.: 300.0 km/h (186.4 mph) | 0.0 km/h (0 mph) | Turn the ignition switch ON and vehicle stopped |
| No significant fluctuation | Vehicle driven at constant speed | ||
| Engine Revolution | Engine revolution Min: 0 rpm Max: 12800 rpm | No significant fluctuation | The engine is running at constant speed |
| Motor Actual Current | Current to motor/ Min.: -327.68 A Max.: 327.67 A | Value changes in proportion to steering effort | The engine is running and power steering is in operation |
| Command Value Current | Requested current to motor/ Min.: -327.68 A Max.: 327.67 A | Value changes in proportion to steering effort | The engine is running and power steering is in operation |
| Thermistor Temperature | ECU substrate temperature/ Min.: -50.0°C (-58°F) Max.: 150.0°C (302°F) | -50.0 to 150.0°C (-58 to 302°F) | - |
| PIG Power Supply | Power source voltage to activate motor/ Min.: 0.0000 V Max.: 20.1531 V | 11 to 14 V | The engine is running |
| IG Power Supply | ECU power source voltage/ Min.: 0.0000 V Max.: 20.1531 V | 11 to 14 V | The engine is running |
| Steering Wheel Torque | Steering wheel torque/ Min.: -327.68 Nm Max.: 7.00 Nm | Value changes in proportion to steering effort | The engine is running and power steering is in operation |
| Torque Sensor 1 Output | Torque sensor 1 output value/ Min.: 0.0000 V Max.: 4.9725 V | 2.3 to 2.7 V | The engine is running and steering wheel not turned (without load) |
| 2.5 to 3.8 V | The engine is running and steering wheel turned to right with vehicle stopped | ||
| 1.2 to 2.5 V | The engine is running and steering wheel turned to left with vehicle stopped | ||
| Torque Sensor 2 Output | Torque sensor 2 output value/ Min.: 0.0000 V Max.: 4.9725 V | 2.3 to 2.7 V | The engine is running and steering wheel not turned (without load) |
| 1.2 to 2.5 V | The engine is running and steering wheel turned to right with vehicle stopped | ||
| 2.5 to 3.8 V | The engine is running and steering wheel turned to left with vehicle stopped | ||
| TRQ1 Zero Point Value | Zero point value of torque sensor 1/ Min.: 0.0000 V Max.: 4.9725 V | 2.3 to 2.7 V | The engine is running and steering wheel not turned (without load) |
| TRQ2 Zero Point Value | Zero point value of torque sensor 2/ Min.: 0.0000 V Max.: 4.9725 V | 2.3 to 2.7 V | The engine is running and steering wheel not turned (without load) |
| Motor Terminal Volt (+) | Motor terminal M1 voltage/ Min.: 0.0 V Max.: 25.5 V | 11 to 14 V | The engine is running and steering wheel turned to right |
| 6 to 11 V | The engine is running and steering wheel turned to left | ||
| Motor Terminal Volt (-) | Motor terminal M2 voltage/ Min.: 0.0 V Max.: 25.5 V | 6 to 11 V | The engine is running and steering wheel turned to right |
| 11 to 14 V | The engine is running and steering wheel turned to left | ||
| IG ON/OFF Times | Number of times of power switch ON/OFF after fail detection/ Min.: 0 times Max.: 65535 times | - | This value indicates the number of times of IG ON/OFF after the latest DTC detection |
| Motor Overheat Record | Continuous overheat prevention control record/ Unrec or Rec | Unrec | - |
| Motor Lo Power Record | PIG power source voltage drop record/ Unrec or Rec | Unrec | - |
| Eng Rev Inter Record | Status of the Record of Engine Revolution Signal Interrupt/ Unrec or Rec | Unrec | - |
| Spd Sig Invalid Record | Vehicle speed signal invalid record/ Unrec or Rec | Unrec | - |
| Battery Voltage Lo Record | Battery voltage drop record/ Min.: 0 times Max.: 65535 times | 0 times | - |
| Stop & Start Control Mode | Status of stop and start system control mode/ IG/Run/Stopreq/Stop/Restart | IG | - |
| The Number of DTCs | Number of detected DTCs when freeze frame data stored/ Min.: 0 Max.: 255 | 0 to 255 | - |