AIR CONDITIONING SYSTEM (for Automatic Air Conditioning System) > CHECK MODE PROCEDURE |
| REFRIGERANT SHORTAGE CHECK IN NORMAL OPERATION (CHECK A/C SWITCH INDICATOR AND DTC) |
![]() |
Turn the ignition switch to ON.
Check that A/C switch indicator is turned on when the following conditions are met.
| Item | Condition |
| A/C Switch | ON |
| A/C driving time | 15 minutes or more |
| Ambient temperature* | 0 to 49°C (32 to 120°F) |
| Engine coolant temperature | 45°C (113°F) or more |
Connect the intelligent tester to the DLC3.
Check for DTC B14B8.
| Result | Amount of Refrigerant | Corrective Action |
| DTC B14B8 is output | Empty or nearly empty | Check for gas leakage using halogen leak detector, and repair if necessary (Click here) |
| DTC B14B8 is not output | Correct or insufficient | Perform the refrigerant shortage check using the intelligent tester |
| REFRIGERANT SHORTAGE CHECK USING THE INTELLIGENT TESTER |
Connect the intelligent tester to the DLC3.
Turn the ignition switch to ON.
Turn the intelligent tester on.
Enter the following menus: Body / Air Conditioner / Utility / Refrigerant Gas Volume Check.
According to the display on the intelligent tester, perform the refrigerant shortage check when the following conditions are met.
| Item | Condition |
| A/C Switch | ON |
| Ambient temperature* | 0 to 49°C (32 to 120°F) |
| R/F Switch | Recirculation (Ambient temperature is 30°C (86°F) or less) |
| Fresh (Ambient temperature is 31°C (87°F) or more) | |
| Blower Speed | HI |
| Temperature Setting | MAX HOT |
| Result | Amount of Refrigerant | Corrective Action |
| The gas volume is insufficient | Insufficient or leakage |
|
| The gas volume is normal | Correct | - |