Home › Vehicle Interior › HEATING / AIR CONDITIONING › AIR CONDITIONING SYSTEM (for Automatic Air Conditioning System)

AIR CONDITIONING SYSTEM (for Automatic Air Conditioning System) > DATA LIST / ACTIVE TEST

for Preparation Click here



DATA LIST

HINT:
Using the intelligent tester to read the Data List allows the values or states of switches, sensors, actuators and other items to be read without removing any parts. This non-intrusive inspection can be very useful because intermittent conditions or signals may be discovered before parts or wiring is disturbed. Reading the Data List information early in troubleshooting is one way to save diagnostic time.

NOTICE:
In the table below, the values listed under "Normal Condition" are reference values. Do not depend solely on these reference values when deciding whether a part is faulty or not.

  1. Connect the intelligent tester to the DLC3.

  2. Turn the ignition switch to ON.

  3. Turn the intelligent tester on.

  4. Enter the following menus: Body / Air Conditioner / Data List.

  5. According to the display on the intelligent tester, read the Data List.

    Air Conditioner 
    Tester Display
    Measurement Item/Range
    Normal Condition
    Diagnostic Note
    Room Temperature Sensor
    Room temperature sensor /
    Min.: -6.5°C (20.3°F)
    Max.: 57.25°C (135.1°F)
    Actual room temperature is displayed
    -
    Ambient Temp Sensor
    Ambient temperature sensor /
    Min.: -23.3°C (-9.94°F)
    Max.: 65.95°C (150.71°F)
    Actual ambient temperature is displayed
    -
    Adjusted Ambient Temp
    Adjusted ambient temperature /
    Min.: -30.8°C (-23.44°F)
    Max.: 50.8°C (123.44°F)
    -
    -
    Evaporator Fin Thermistor
    Evaporator temperature sensor /
    Min.: -29.7°C (-21.46°F)
    Max.: 59.55°C (139.19°F)
    Actual evaporator temperature displayed
    Open in the circuit: -29.7°C (-21.46°F).
    Short in the circuit: 59.55°C (139.19°F).
    Evaporator Target Temp
    Target evaporator temperature /
    Min.: -327.68°C (-557.82°F)
    Max.: 327.67°C (621.81°F)
    Target evaporator temperature displayed
    -
    Solar Sensor (D side)
    Driver side solar sensor /
    Min.: 0
    Max.: 255
    Driver side solar sensor value increases as brightness increases
    -
    Engine Coolant Temp
    Engine coolant temperature /
    Min.: 1.3°C (34.34°F)
    Max.: 90.55°C (194.99°F)
    Actual engine coolant temperature is displayed after engine warmed up
    -
    Set Temperature (D side)
    Driver side set temperature /
    Min.: MAX COLD
    Max.: MAX HOT
    Driver side actual set temperature is displayed
    -
    Blower Motor Speed Level
    Blower motor speed level /
    Min.: 0
    Max.: 31
    Increases from 0 to 31 as blower motor speed increases
    -
    Regulator Pressure Sensor
    Regulator pressure sensor /
    Min.: -0.4566 MPaG
    Max.: 3.2943 MPaG
    Actual regulator pressure is displayed
    -
    Regulator Control Current
    Regulator control current /
    Min.: 0 A
    Max.: 0.997 A
    Value changes between 0.12 A and 0.997 A in accordance with compressor operation
    -
    Air Mix Servo Targ Pulse (D)
    Air mix servo motor target pulse /
    Min.: 0
    Max.: 255
    1. MAX COOL: 4 (pulse)
    2. MAX HOT: 93 (pulse)
    -
    Air Mix Servo Actual Pulse (D)
    Air mix servo motor actual pulse /
    Min.: 0
    Max.: 255
    Follows the target pulse
    -
    Air Outlet Servo Pulse (D)
    Air outlet servo motor target pulse /
    Min.: 0
    Max.: 255
    1. FACE: 101 (pulse)
    2. B/L: 74 (pulse)
    3. FOOT: 53 or 62 (pulse)
    4. FOOT / DEF: 35 (pulse)
    5. DEF: 9 (pulse)
    -
    Air Outlet Servo Actu Pulse (D)
    Air outlet servo motor actual pulse /
    Min.: 0
    Max.: 255
    Follows the target pulse
    -
    Air Inlet Damper Targ Pulse
    Air inlet servo motor target pulse /
    Min.: 0
    Max.: 255
    1. Recirculation: 6 (pulse)
    2. Fresh: 22 (pulse)
    -
    Air Inlet Damper Actual Pulse
    Air inlet servo motor actual pulse /
    Min.: 0
    Max.: 255
    Follows the target pulse
    -
    Shift Set Temperature
    Set temperature shift /
    2C decr, 1C decr, Normal, 1C incr or 2C incr
    Customized value displayed
    -
    Air Inlet Mode
    Air inlet mode /
    Auto or Manual
    Customized value displayed
    -
    Evaporator Control
    Evaporator Control /
    Auto or Manual
    Customized value displayed
    -
    Refrigerant Shortage Check
    Refrigerant shortage check function /
    ON or OFF
    Customized value displayed
    -
    Fan Speed Increment Control
    Blower motor speed increment level to target speed /
    Fast, Normal or Slow
    Customized value displayed
    -
    Foot/DEF Auto Mode
    Foot / DEF auto mode /
    ON or OFF
    Customized value displayed
    -
    Foot/DEF Auto Blow Up
    Foot / DEF automatic blow up function /
    ON or OFF
    Customized value displayed
    -
    Pls Servo Test Sts
    Pulse servo motor test status / Wait, Move, Comp, Error or Stop
    Pulse servo motor test status
    -
    A/C Cutoff Signal
    A/C control cutoff signal /
    ON or OFF
    -
    -
    Number of Trouble Codes
    Number of trouble codes /
    Min.: 0
    Max.: 255
    Number of DTCs displayed
    -


ACTIVE TEST

HINT:
Using the intelligent tester to perform Active Tests allows relays, VSVs, actuators and other items to be operated without removing any parts. This non-intrusive functional inspection can be very useful because intermittent operation may be discovered before parts or wiring is disturbed. Performing Active Tests early in troubleshooting is one way to save diagnostic time. Data List information can be displayed while performing Active Tests.

  1. Connect the intelligent tester to the DLC3.

  2. Turn the ignition switch to ON.

  3. Turn the intelligent tester on.

  4. Enter the following menus: Air Conditioner: Body / Air Conditioner / Active Test.

  5. According to the display on the intelligent tester, perform the Active Test.

    Air Conditioner 
    Tester Display
    Test Part
    Control Range
    Diagnostic Note
    Blower Motor
    Blower motor
    Min.: 0, Max.: 31
    -
    Magnetic Clutch Relay
    A/C Compressor
    OFF or ON
    -
    Defogger Relay (Rear)
    Defogger relay (Rear)
    OFF or ON
    -
    Air Mix Servo Targ Pulse (D)
    Air mix servo motor pulse
    Min.: 0, Max.: 255
    Perform Active Test when value between 4 and 93 displayed
    Air Outlet Servo Pulse (D)
    Air outlet servo motor pulse
    Min.: 0, Max.: 255
    Perform Active Test when value between 9 and 101 displayed
    Air Inlet Damper Targ Pulse
    Air inlet damper target pulse
    Min.: 0, Max.: 255
    Perform Active Test when value between 6 and 22 displayed