COMPRESSOR (for 1NZ-FE, 2NZ-FE) > REMOVAL |
| 1. RECOVER REFRIGERANT FROM REFRIGERATION SYSTEM |
Start up the engine.
A/C switch on.
Turn the blower switch to on.
Operate the cooler compressor with an engine speed of approximately 1000 rpm for 5 to 6 minutes to circulate the refrigerant and collect the remaining compressor oil from each component, in the cooler compressor.
Stop the engine.
![]() |
Remove the caps from the service valves on the refrigerant line.
| *1 | High Pressure Service Valve |
| *2 | Low Pressure Service Valve |
Connect the refrigerant recovery unit.
Recover the refrigerant from the air conditioning system using a refrigerant recovery unit.
| 2. REMOVE FAN AND GENERATOR V BELT |
| 3. REMOVE ENGINE UNDER COVER RH (for Plastic Type) |
| 4. REMOVE NO. 1 ENGINE UNDER COVER SUB-ASSEMBLY (for Metal Type) |
| 5. DISCONNECT SUCTION HOSE SUB-ASSEMBLY (w/o Fan Shroud Ventilation Duct) |
![]() |
Remove the bolt and disconnect the suction hose from the compressor.
Remove the O-ring from the suction hose.
| 6. DISCONNECT SUCTION HOSE SUB-ASSEMBLY (w/ Fan Shroud Ventilation Duct) |
![]() |
Remove the bolt and disconnect the suction hose from the compressor.
Remove the O-ring from the suction hose.
| 7. DISCONNECT NO. 1 COOLER REFRIGERANT DISCHARGE HOSE (w/o Fan Shroud Ventilation Duct) |
![]() |
Remove the bolt and disconnect the discharge hose from the compressor.
Remove the O-ring from the discharge hose.
| 8. DISCONNECT NO. 1 COOLER REFRIGERANT DISCHARGE HOSE (w/ Fan Shroud Ventilation Duct) |
![]() |
Remove the bolt and disconnect the discharge hose from the compressor.
Remove the O-ring from the discharge hose.
| 9. REMOVE COMPRESSOR WITH PULLEY ASSEMBLY |
Disconnect the connector.
![]() |
Remove the 4 bolts and the compressor.