AIR CONDITIONING PRESSURE SENSOR > INSTALLATION |
| 1. INSTALL AIR CONDITIONER PRESSURE SENSOR |
Remove the attached vinyl tape from the tube and the connecting part of the cooler condenser.
Apply sufficient compressor oil to a new O-ring and the fitting surface of the tube joint.
![]() |
Using a deep socket wrench 27 mm, install the pressure sensor.
| *a | Turn |
| *b | Hold |
Connect the connector.
| 2. CHARGE REFRIGERANT |

Perform vacuum purging using a vacuum pump.
Charge refrigerant HFC-134a (R134a).
| Item | Refrigerant Charging Amount |
| w/o Fan Shroud Ventilation Duct | 330 to 390 g (11.6 to 13.8 oz.) |
| w/ Fan Shroud Ventilation Duct | 350 to 410 g (12.3 to 14.5 oz.) |

Install the caps onto the service valves on the refrigerant line.
| 3. WARM UP ENGINE |
| 4. INSPECT FOR REFRIGERANT LEAK |
After recharging the refrigerant gas, check for refrigerant gas leakage using a halogen leak detector.
Perform the operation as follows:
![]() |
Using the halogen leak detector, check the refrigerant line, especially at the connection points, for leakage.
| *1 | Halogen Leak Detector |
![]() |
Bring the halogen leak detector close to the drain hose before performing the test.
| *1 | Drain Hose |
| *2 | Halogen Leak Detector |
If no gas leakage is detected from the drain hose, remove the blower motor from the cooling unit. Insert the halogen leak detector sensor into the unit and perform the test.
Disconnect the pressure switch connector and leave it for approximately 20 minutes. Bring the halogen leak detector close to the pressure switch and perform the test.