Home › Engine / Hybrid System · 2NZ-FE › ENGINE CONTROL › KNOCK SENSOR

KNOCK SENSOR > INSPECTION

for Preparation Click here



1. INSPECT KNOCK SENSOR


    A093606E17
  1. Measure the resistance according to the value(s) in the table below.
    Text in Illustration 
    *a
    Component without harness connected
    (Knock Sensor)

    Standard Resistance:
    Tester Connection
    Condition
    Specified Condition
    1 - 2
    20°C (68°F)
    120 to 280 kΩ

    If the result is not as specified, replace the knock sensor.