REFRIGERANT LINE > INSTALLATION |
| 1. INSTALL PIPING CLAMP |
![]() |
Install a new piping clamp onto the suction hose.
| *1 | Piping Clamp |
| *2 | Groove |
| *3 | Suction Hose |
Remove the vinyl tape from the open ends of the suction tube and suction hose.
Thoroughly coat a new O-ring and the contact surface of the suction hose with compressor oil (ND-OIL8).
Install the 2 O-rings onto the suction hose.
![]() |
Engage the suction tube and suction hose by matching the alignment marks.
| *1 | Large Diameter Section of Piping Clamp |
| *2 | Alignment Mark |
| *3 | Alignment Mark (yellow) |
![]() |
Securely insert the piping clamp to the point where the large diameter section of the piping clamp is covered by the suction tube.
| *1 | Large Diameter Section of Piping Clamp |