COOLER EXPANSION VALVE > REMOVAL |
| 1. RECOVER REFRIGERANT FROM REFRIGERATION SYSTEM |
Start up the engine.
A/C switch on.
Turn the blower switch to on.
Operate the cooler compressor with an engine speed of approximately 1000 rpm for 5 to 6 minutes to circulate the refrigerant and collect the remaining compressor oil from each component, in the cooler compressor.
Stop the engine.
![]() |
Remove the caps from the service valves on the refrigerant line.
| *1 | High Pressure Service Valve |
| *2 | Low Pressure Service Valve |
Connect the refrigerant recovery unit.
Recover the refrigerant from the air conditioning system using a refrigerant recovery unit.
| 2. DISCONNECT SUCTION TUBE SUB-ASSEMBLY B |
![]() |
Remove the bolt.
Turn the hook connector clockwise and disconnect the suction tube.
Remove the O-ring from the suction tube.
| 3. DISCONNECT LIQUID TUBE SUB-ASSEMBLY A |
Disconnect the liquid tube.
Remove the O-ring from the liquid tube.
| 4. REMOVE COOLER EXPANSION VALVE |
![]() |
Using a 4 mm hexagon wrench, remove the 2 hexagon bolts.
![]() |
Temporarily attach the bolt for the suction tube sub-assembly halfway to the cooler expansion valve.
| *1 | Bolt For The Suction Tube Sub-assembly |
![]() |
Hold the bolt and pull it to remove the cooler expansion valve as shown in the illustration.
![]() |
Remove the 2 O-rings from the cooler evaporator.
| *1 | Cooler Evaporator |