HAZARD WARNING SWITCH > INSPECTION |
| 1. INSPECT HAZARD WARNING SIGNAL SWITCH ASSEMBLY |
![]() |
Check the hazard warning signal light switch function.
| *a | Component without harness connected (Hazard Warning Signal Switch Assembly) |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| 1(E) - 4(TB) | Pushed | Below 1 Ω |
| Not pushed | 10 kΩ or higher |
![]() |
Check the illumination operation.
| *a | Component without harness connected (Hazard Warning Signal Switch Assembly) |
Apply battery voltage to the hazard warning signal light switch assembly connector.
| Measurement Condition | Specified Condition |
| Battery positive (+) → 3(ILL+) Battery positive (-) → 2(ILL-) | The illumination comes on |