Symptom
|
Possible cause
|
Remedy
|
One lamp does not light (all exterior)
|
Bulb burned out Socket,
wiring or ground faulty
|
Replace bulb Repair if
necessary
|
Head lamps do not light
|
Bulb burned out No.10 fuse
(10A) blown Fusible link (50A)
blown Head lamp relay
faulty Lighting switch
faulty Wiring or ground
faulty
|
Replace bulb Check for
short and replace fuse Replace the
fusible link Check
relay Check switch Repair if necessary
|
Tail lamps and license plate lamps do not
light
|
Tail lamp fuse (10A) blown Battery fusible link (50A) blown Tail
lamp relay faulty Lighting switch
faulty Wiring or ground
faulty
|
Replace fuse and check for short Replace
the fusible link Check
relay Check switch Repair if necessary
|
Stop lamps do not light
|
No.8 fuse (10A) blown Stop
lamp switch faulty Wiring or ground
faulty
|
Replace fuse and check for short Adjust
or replace switch Repair if
necessary
|
Stop lamps stay on
|
Stop lamp switch faulty
|
Adjust or replace switch
|
Instrument lamps do not light (Tail
lamps light)
|
Rheostat faulty Wiring or
ground faulty
|
Check rheostat Repair if
necessary
|
Turn signal lamp does not flash on one
side
|
Bulb burned out Turn
signal switch faulty Wiring or ground
faulty
|
Replace bulb Check
switch Repair if
necessary
|
Turn signal lamps do not operate
|
No.1 fuse (10A) blown Flasher unit faulty Turn
signal switch faulty Wiring or ground
faulty
|
Replace fuse and check for short Check
flasher unit Check
switch Repair if
necessary
|
Hazard warning lamps do not operate
|
No.7 fuse (10A) blown Flasher unit faulty Hazard
switch faulty Hazard relay
faulty Wiring or ground
faulty
|
Replace fuse and check for short Check
flasher unit Check
switch Replace relay Repair if necessary
|
Flasher rate too slow or too fast
|
Lamps' wattages are smaller or larger than
specified Defective flasher
unit
|
Replace lamps
Check
flasher unit
|
Back up lamps do not light up
|
No.5 fuse (10A) blown Back
up lamp switch faulty Wiring or ground
faulty
|
Replace fuse and check for short Check
switch Repair if
necessary
|
Room lamp does not light up
|
Room lamp fuse (10A) blown Wiring or ground faulty
|
Replace fuse and check for short Repair
if necessary
|