| BATTERY VISUAL INSPECTION
(1) |

BATTERY
VISUAL INSPECTION (2)
| 1. |
Make sure ignition switch is in the Off
position and all accessories are
Off. |
| 2. |
Disconnect the battery cables. (negative
first) |
| 3. |
Remove the battery from the
vehicle.
|
Care should be taken in the event that
the battery case is cracked or leaking, to protect your skin
from the electrolyte. A suitable pair of rubber gloves (not
household type) should be worn when removing the
battery.

| |
| 4. |
Inspect the battery carrier for damage
caused by the loss of acid from the battery. If acid damage is
present, it will be necessary to clean the area with a solution of
clean, warm water and baking soda. Scrub the area with a stiff brush
and wipe off with a cloth moistened with baking soda and
water. |
| 5. |
Clean the top of the battery with the same
solution as described in step 4. |
| 6. |
Inspect the battery case, and cover, for
cracks. If cracks are present, the battery must be
replaced. |
| 7. |
Clean the battery posts with a suitable
battery post cleaner. |
| 8. |
Clean the inside surface of the terminal
clamps with a suitable battery terminal cleaning tool. Replace
damaged or frayed cables and broken terminal
clamps. |
| 9. |
Install the battery in the
vehicle. |
| 10. |
Connect the cable terminals to the battery
post, making sure the top of the terminals are flush with the top of
the post. |
| 11. |
Tighten the terminal nut
securely. |
| 12. |
Coat all connections with light mineral
grease after tightening.
|
When batteries are being charged, an
explosive gas forms beneath the cover of each cell. Do not
smoke near batteries being charged or which have recently been
charged. Do not break live circuits at the terminals of the
batteries being charged. A spark will occur where the circuit
is broken. Keep all flames away from an open
battery.

| |
SPECIFIC
GRAVITY CHECK CHART
|
A difference of 50 points (0.050) or more
between one or more cells indicates a defective battery. It should
be replaced.

|
Specific
gravity
|
Charge
method
|
Slow charge
(5A)
|
Fast charge
(20A)
|
Below 1.100
|
14 hours
|
4 hours
|
100 ~ 1.130
|
12 hours
|
3 hours
|
130 ~ 1.160
|
10 hours
|
2.5 hours
|
160 ~ 1.190
|
8 hours
|
2.0 hours
|
190 ~ 1.220
|
6 hours
|
1.5 hours
|
Above 1.220
|
4 hours
|
1.0 hours
|