SERVICE
ADJUSTMENT PROCEDURES FOR PINION GAP ADJUSTMENT
| 1. |
Disconnect the field coil wire from the
M-terminal of the solenoid. |
| 2. |
Connect a 12V battery the S-terminal and the
M-terminal. |
| 3. |
The pinion will move out.
|
This test must be performed quickly
(in less than 10 seconds) to prevent the coil from
burning.

| |
| 4. |
Check the pinion for stopper clearance
(pinion gap) with a feeler gauge.
: 0.5 ~ 2.0 mm (0.02 ~ 0.079
in.)
|

|
| 5. |
If the pinion gap is out of specification,
adjust by adding or removing gaskets between the solenoid and the
front bracket.

|
MAGNETIC
SWITCH PULL-IN TEST
| 1. |
Disconnect the field coil wire from the
M-terminal of the magnetic switch. |
| 2. |
Connect a 12V battery between the S-terminal
and the M- terminal.
|
This test must be performed quickly
(in less than 10 seconds) to prevent the coil from
burning. | |
| 3. |
If the pinion moves out, then the pull-in
coil is good. If it doesn't move out, replace the magnetic
switch.

|
MAGNETIC
SWITCH HOLD-IN TEST
| 1. |
Disconnect the field coil wire from the
M-terminal of the magnetic switch. |
| 2. |
Connect a 12V battery between the S-terminal
and the body.
|
This test must be performed quickly
(in less than 10 seconds) to prevent the coil from
burning. | |
| 3. |
If the pinion moves out, everything is in
order. If the pinion moves back and forth repeatedly, the hold-in
circuit is open. Then replace the magnetic switch.

|
FREE
RUNNING TEST
| 1. |
Place the starter motor in a vise equipped
with soft jaws and connect a fully-charged 12-volt battery to
starter motor as follows: |
| 2. |
Connect a test ammeter (100-ampere scale)
and carbon pile rheostat as shown is the
illustration. |
| 3. |
Connect a voltmeter (15-volt scale) across
starter motor. |
| 4. |
Rotate carbon pile to the off
position. |
| 5. |
Connect the battery cable from battery's
negative post to the starter motor
body. |
| 6. |
Adjust until battery voltage shown on the
voltmeter reads 11 volts. |
| 7. |
Confirm that the maximum amperage is within
the specifications and that thestarter motor turns smoothly and
freely:
Max. 90 Amps Min.
2,800 Amps
|

|
MAGNETIC
SWITCH RETURN TEST
| 1. |
Disconnect field coil wire from the
M-terminal of the magnetic switch. |
| 2. |
Connect a 12V battery between M-terminal and
the body.
|
This test must be performed quickly
(in less than 10 seconds) to prevent the coil from
burning. | |
| 3. |
Pull pinion out and release. If pinion
returns quickly to its original position, everything is in order. If
it doesn't, replace the magnetic switch.

|