The diagnosis module
comprises an electromechanically driven pump together with a change-over
valve and heater.
The engine management
system measures the pump's electrical current consumption while pumping
air into the canister and fuel tank to check the system's
leakage.
If the electrical
current consumption is over the threshold value specified before in the
memory, this means that there is a tank-system leak.
TROUBLESHOOTING
HINTS
HARNESS